– 55 –
KP-FX43M31/M61/M91
KP-FX53M31/M61/M91
RM-998
ERROR
DESCRIPTION
NOTE
CODE
10
Sensor 0 low output
Check sensor 0, connection/Wiring, circuit and pattern position.
(Are patterns hitting sensor ?) Adjust V UP, HMID if necessary.
11
Sensor 1 low output
Check sensor 1, connection/Wiring, circuit and pattern position.
(Are patterns hitting sensor ?) Adjust HLE, VMID if necessary.
12
Sensor 2 low output
Check sensor 2, connection/Wiring, circuit and pattern position.
(Are patterns hitting sensor ?) Adjust HRIV, VMID if necessary.
13
Sensor 3 low output
Check sensor 3, connection/Wiring, circuit and pattern position.
(Are patterns hitting sensor ?) Adjust VLOW, HMID if necessary.
20
Sensor 0 high output
Check sensor 0 and circuit.
21
Sensor 1 high output
Check sensor 1 and circuit.
22
Sensor 2 high output
Check sensor 2 and circuit.
23
Sensor 3 high output
Check sensor 3 and circuit.
30
V center or skew adjustment
Check VMID data and check registration condition.
loop overflow
31
H center or skew adjustment
Check HMID data and check registration condition.
loop overflow
32
H linearity or size adjustment
Check HLE and HRIV data and check registration condition.
loop overflow
40
V center regi data overflow
Check VMID data and confirm V center data (all modes) is not near 511.
41
H center regi data overflow
Check HMID data and confirm H center data (all modes) is not near 511.
42
V skew regi data overflow
Check VMID data and confirm V skew data (all modes) is not near 511.
43
H skew regi data overflow
Check HMID data and confirm H skew data (all modes) is not near 511.
44
H linearity regi data overflow
Check HLE data and HRIV data and confirm H center data (all modes)
is not near 511.
45
H size regi data overflow
Check HLE data and HRIV data and confirm H center data (all modes)
is not near 511.
50
V center regi data overflow
Check VMID data and confirm V center data (all modes) is not near 512.
51
H center regi data overflow
Check HMID data and confirm H center data (all modes) is not near 512.
52
V skew regi data overflow
Check VMID data and confirm V skew data (all modes) is not near 512.
53
H center regi data overflow
Check HMID data and confirm H skew data (all modes) is not near 512.
54
H linearity regi data overflow
Check HLE data and HRIV data and confirm H center data (all modes)
is not near 512.
55
H size regi data overflow
Check HLE data and HRIV data and confirm V center data (all modes)
is not near 512.
60
Cent/Skew calibration loop
Check HMID and VMID data and check registration condition.
overflow
61
Size/Lin calibration loop
Check HLE, HRIV, VUP, and VLOW data and check registration
overflow
condition.
70
V cent/Skew ratio limit
Check sensors 1 and 2, connection/wiring, circuit, increase RTLM.
71
H cent/Skew ratio limit
Check sensors 0 and 3, connection/wiring, circuit, increase RTLM.
73
H size/Lin ratio limit
Check sensors 1 and 2, connection/wiring, circuit, increase RTLM.
80
Size limit Error
Check that horizontal size data is not near SZLM.
ERROR CODE LIST
0 : UPPER SENSOR
1 : LEFT SENSOR
2 : RIGHT SENSOR
3 : LOWER SENSOR
SCREEN
0
3
1
2
[SENSOR POSITION]
PJE
61
133
ERR
|
Category : PJE
Item : 61 ERR
Color : (0=G, 1=R, 2=b, 3=ALL)
Error code : (See Error codelist)
133
• ERROR CODE SCREEN DISPLAY
(When select “PJE”
b
“61 ERR”.)
Horizintal/Vertical
R, G, B
Sensor 0/1/2/3
Ratio Offset
RORH
R0RH
• ERROR CODE SCREEN DISPLAY
(When press “
(AUTO CONVERGENCE)” button.)
3-16. AUTO CONVERGENCE ERROR CODE LIST
If an error code is displayed after the set has been fully adjusted, correctly, plese check the following items : position, tilt and sizing. If
either of these adjustments are off, even slightli, the auto registration pattern will not hit the four sensors properly. This occurs when the
internal generator patterns is being flashed on the screen for the sensor to read. Therefore, auto registration (called auto convergence)
cannot operate properly causing an error code to be displayed. In order for this function to operate properly, correct position, tilt and size
must be adjusted properly.