96
Connectors
Input Connectors
SDI (BNC type) (2)
DVI-D (Single link) (2)
S VIDEO (Mini DIN 4-pin type) (1)
Y: 1.0 Vp-p (75
Ω
) Sync negative
C (BURST): 0.286 Vp-p (75
Ω
) (NTSC)
C (BURST): 0.3 Vp-p (75
Ω
) (PAL)
VIDEO (BNC type) (1)
Composite
1.0 Vp-p (75
Ω
)
Sync negative
AUDIO (Stereo mini jack) (1)
MIC (Stereo mini jack) (1)
RGB (Mini D-Sub 15-pin) (1)
AC Inlet (3-pin) (1)
Output Connectors
SDI (BNC type) (1)
DVI-D (Single link) (1)
S VIDEO (Mini DIN 4-pin type) (1)
Y: 1.0 Vp-p (75
Ω
) Sync negative
C (BURST): 0.286 Vp-p (75
Ω
) (NTSC)
C (BURST): 0.3 Vp-p (75
Ω
) (PAL)
VIDEO (BNC type) (1)
Composite
1.0 Vp-p (75
Ω
)
Sync negative
AUDIO (Stereo mini jack) (1)
Other Interfaces
USB 3.0 (Type A) (2)
USB 2.0 (Type A) (4)
USB 2.0 (Type B) (1)
Network (RJ-45, 1000 Base-T/100 Base-TX) (1)
REMOTE RS-232C (D-Sub 9-pin) (1)
REMOTE contact switch (Stereo mini jack) (4)
MENU MONITOR (Mini D-Sub 15-pin) (1)
Equipotential
General
Power Requirements
100 V to 240 V AC, 50/60 Hz
Input Current
1.25 A to 0.52 A
Operating Temperature
5 °C to 40 °C (41 °F to 104 °F)
Operating Humidity
20% to 80% (Maximum wet-bulb temperature: 30 °C
(86 °F)) (no condensation allowed)
Operating Pressure
700 hPa to 1,060 hPa
Storage and Transport Temperature
–20 °C to +60 °C (–4 °F to +140 °F)
Storage and Transport Humidity
20% to 90% (Maximum wet-bulb temperature: 30 °C
(86 °F)) (no condensation allowed)
Storage and Transport Pressure
700 hPa to 1,060 hPa
Mass
Approx. 6.5 kg (Approx. 14 lb. 5.3 oz.)
Dimensions
305.0 × 329.0 × 115.5 mm (12
1
/
8
× 13 × 4
5
/
8
in.)
(W × D × H) (including longest protrusions)
Supplied Items
Before Using This Unit (1)
CD-ROM (Instructions for Use, PROTOCOL
MANUAL) (1)
Warranty booklet (1)
Service Contact List (1)
Infrared remote control unit (RM-M010) (1)
Information for Customers in Europe (1)
REMOTE contact switch connectors
Connector specifications (stereo mini jack)
1 GND
2 TRIGGER SIGNAL (TTL)
If the status changes for at least 100 msec, the action
configured in the REMOTE contact switch settings will
start.
3 BUSY STATUS (TTL)
HIGH level will be initiated according to the REMOTE
contact switch settings.
Medical Specifications
Protection against electric shock:
Class I
Protection against harmful ingress of water:
Ordinary
Degree of safety in the presence of flammable
anesthetics mixtures with air or with oxygen or
nitrous oxide:
Not suitable for use in the presence of flammable
anesthetics mixture with air or with oxygen or
nitrous oxide
Mode of operation:
Continuous
Design and specifications are subject to change without
notice.
3
2
1