Warning/Error Messages
157
Ap
pend
ix
es
If low battery power is detected, or if an error or other abnormal condition occurs on power on or during
operation, the RUN indicator flashes and alarm message flash in the viewfinder, on the external monitor,
and in the subdisplay.
When the unit stops operating correctly because
of an internal error, a warning tone sounds and a
popup window appears on the display of the
control panel with an error message.
Only one message is displayed at one time, even
if multiple errors occur. But the number of current
errors appears at the bottom of the popup
window.
At the same time, a VTR module error message
appears in the viewfinder and in the message
display section of the monitor screen.
Warning/Error Messages
Errors Detected in the Camera Module
Viewfinder screen
Subdisplay
RUN indicator
Meaning
Basic status
display
Message
BATT flashes
BATT flashes
Flashes
Power voltage is low (has
reached the specified NEAR
END value).
BATT flashes
BATT quickly Flashes quickly
Power voltage is exhausted
(has reached the specified END
value).
TEMPERATURE
CARE
The temperature inside the unit
is high.
TEMP WARNING/
FAN MAX
The temperature inside the unit
has risen to the limit. FAN
MODE has been forcibly set to
MAX.
SHUTDOWN
CAMERA/FAN MAX
The unit must be powered off
for safety. FAN MODE has
been forcibly set to MAX.
OHB FAN NG!
The fan near the CCD has
stopped.
MAIN FAN NG!
The fan in the main unit has
stopped.
CAM?
OHB NG!
CCD unit error
CAM?
AD BOARD NG!
AD board error
CAM?
VDA BOARD NG!
VDA board error
CAM?
VPR BOARD NG!
VPR board error
VTR ALARM
Alarm in the VTR module
VTR WARNING
Warning in the VTR module
Errors Detected in the VTR
Module
Содержание HKSR-9003