![Sony HDVF-C950W Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/sony/hdvf-c950w/hdvf-c950w_maintenance-manual_393456012.webp)
1-6 (E)
HDVF-C950W
Used equipment
.
PLD download tool (Sony part No. : J-7120-140-A)
Cable to connect PC and the device
.
PC
Computer with a parallel port.
Computer with PLD Download Tool installed.
For the supported OS and operating environment, refer
to “Download Tool Operation Manual (Device Writing
Volume)”.
Operation procedure
The procedure to write data to the PLD (or the ROM for
the PLD) is outlined below.
For details on these steps, refer to “Download Tool
Operation Manual (Device Writing Volume)”.
“Download Tool Operation Manual (Device Writing
Volume)” can be obtained on the same Web site where the
PLD Download Tool software is downloaded.
Step 1. Prepare the Project file.
n
Download the Project file from the Sony database
server.
Step 2. With the power of the device turned off, connect
the parallel port on the PC and the EPR connector
on the target board with the PLD download tool
(cable).
Step 3. Turn on the power of the device.
Launch the PLD Download Tool software, and
import the Project file.
Step 4. Program the PLD (or the ROM for the PLD) by
using the PLD Download Tool software.
Step 5. When the programming completes correctly
(without an error message), restart the device.