SECTION 4
TEST MODE
1. TEST MODES OTHER THAN THE TEST MENU
These are executable test mode even if not entering the test menu.
1-1. Cold Reset
The cold reset clears data except DVD data stored in the RAM to
initial conditions. Execute this mode when returning the set to the
customers.
Procedure:
1. In the standby state, the
I
/1
button on the set is pressed for
5 seconds or more.
2. The messages “MEMORY CLR” and “PUSH POWER” are
displayed on the fluorescent indicator tube.
3. When the
I
/1
button is pressed in the state of step 2, the
messages “CLEARING”
t
“CLEARED!” are displayed, then
becomes standby states.
1-2. DVD Version View
Procedure:
1. Connect the set with the TV screen.
2. In the standby state, Press the button in order of the
[ DISPLAY]
t
[ENTER]
t
I
/1
on the remote commander, the DVD
version appears on the TV screen.
3. To release from this mode, press the
I
/1
button.
1-3. AM Step Change (US and Canadian models)
The step interval of AM channels can be toggled between 9 kHz
and 10 kHz.
Procedure:
1. Press the
I
/1
button to turn the power on.
2. Press the
[FUNCTION]
button on the remote commander to
select the “AM”.
3. Press the
[TUNER MENU]
button on the remote commander
and press the
M
m
button on the remote commander to
select the “AM step?”, and press the
3
button on the remote
commander.
4. The message “10k
t
9k” or “9k
t
10k” appears on the
fluorescent indicator tube.
5. Press the
3
button on the remote commander, and the AM
channel step is changed.
1-4. Disc Tray Lock
This mode let you lock the disc tray. When this mode is activated,
the disc tray will not eject when the
Z
sensor is touched. The
message “LOCKED” will be displayed on the fluorescent indicator
tube.
Procedure:
button to turn the power on.
button on the remote commander to
sensors and press the
I
/1
button on
the set simultaneously and hold down until “LOCKED” or
“UNLOCKED” displayed on the fluorescent indicator tube
(around 5 seconds).
Mode to prevent theft of the demonstration disc.
Setting Procedure:
It automatically enters the mode when the demonstration disc is
inserted.
Releasing Procedure:
1. Press the
I
/1
button to turn the power on.
2. Press the
[FUNCTION]
button on the remote commander to
select the “DVD”.
3. Touch the
x
and
N
sensor on the set simultaneously and
hold down until “DEMO OFF” displayed on the fluorescent
indicator tube (around 5 seconds).
2. TEST MODES IN THE TEST MENU
These are the test modes done in the test menu.
Setting method of the test menu:
1. Press th
I
/1
button to turn the power on.
2. Press the button in order of the
[CLEAR]
t
[ENTER]
t
[0]
t
[1]
t
[0]
t
[ANGLE]
on the remote commander. (Make
the interval when each button is pressed within two seconds.)
3. The message “TEST MENU” appears on the fluorescent indi-
cator tube and enter the test menu.
2-1. Panel Test
Procedure:
1. Enter the test menu.
2. Press the
M
m
button on the remote commander to select the
“PANEL TEST”, and press the
[ENTER]
button on the remote
commander.
3. LEDs (except
N
and
Z
) and all segments in fluorescent
indicator tube are lighted up. And
N
LED and half seg-
ments in fluorescent indicator tube are lighted up,
Z
LED
and others half segments in fluorescent indicator tube are light-
ed up, then LEDs (except
N
and
Z
) and all segments in
fluorescent indicator tube are lighted up. This operation is
repeated.
4. When all segments in fluorescent indicator tube are light-
ed up in the state of step 3, press the
[]
button
on the remote commander and model information is dis-
played on the fluorescent indicator tube.
Each time the
[]
button on the remote commander
is pressed, the display changes from destination information,
MC version, SYS version, UI version, DVD version, ST ver-
sion, TA version, DSP version, TM version, CLA version, CEC
version in this order, and returns to the model information
display.
Each time the
[VOLUME ---]
button on the remote commander
is pressed, the version and date are switched.
5. In the state of step 3, press the
[FUNCTION]
button on the
remote commander and “K 0” is displayed on the fluorescent
indicator tube.
“K 0” value increases whenever a button on the set is pressed
or a sensor is touched. However, once a button has been
pressed, it is no longer taken into account.
The
I
/1
button on the set is pressed and all sensors are
touched, “OK” and “K 9” are alternately displayed on the flu-
orescent indicator tube.
6. To release from this mode, press the
I
/1
button.
2-2. Amp Test
Procedure:
1. Enter the test menu.
2. Press the
M
m
button on the remote commander to select
the “AMP TEST”, and press the
[ENTER]
button on the re-
mote commander.
3. The message “MEASURE” appears on the fluorescent indi-
cator tube and enter the amp test mode.
4. Press the
[SUBTITLE]
button on the remote commander, the
message “VACS ON” or “VACS OFF” appears on the fluo-
rescent indicator tube and thus the VACS on/off are changed.
5. To release from this mode, press the
I
/1
button.