14. ERROR RATE CHECK
14-1. CD Error Rate Check
Procedure:
1. Load the check disc (TDYS-1).
2. Press the
.
“R”
or
>
“R”
button and display “CPLAY1
MODE” (C34).
3. Press the
ENTER/YES “R”
button twice and display “CPLAY1
MID”.
4. The display changes to “C =
AD =
)”.
5. Check that the C1 error rate is below 50.
6. Press the
MENU/NO “R”
button to stop playback, then press the
Z
(MD) button and take out the check disc.
14-2. MO Error Rate Check
Procedure:
1. Load the continuously-recorded disc. (Refer to “5. USING
THE CONTINUOUSLY RECORDED DISC” (See page 31))
2. Press the
.
“R”
or
>
“R”
button to display “CPLAY1
MODE” (C34).
3. Press the
ENTER/YES “R”
button to display “CPLAY1MID”.
4. The display changes to “C1 =
AD =
)”.
5. If the C1 error rate is below 50, check that ADER is 00.
6. Press the
MENU/NO “R”
button to stop playback, then press the
Z
(MD) button and take out the disc.
15. FOCUS BIAS CHECK
Change the focus bias and check the focus tolerance amount.
Procedure:
1. Load the continuously-recorded disc. (Refer to “5. USING
THE CONTINUOUSLY RECORDED DISC” (See page 31))
2. Press the
.
“R”
or
>
“R”
button to display “CPLAY1
MODE” (C34).
3. Press the
ENTER/YES “R”
button twice to display “CPLAY1
MID”.
4. Press the
MENU/NO “R”
button when “C1 =
AD =
)”
is displayed.
5. Press the
.
“R”
or
>
“R”
button to display “FBIAS
CHECK” (C16).
6. Press the
ENTER/YES “R”
button to display “
/
c =
”.
The first four digits indicate the C1 error rate, the two digits
after “/ ” indicate ADER, and the 2 digits after “c =” indicate
the focus bias value.
Check that the C1 error is below 50 and ADER is below 2.
7. Press the
ENTER/YES “R”
button and display “
/
b =
”.
Check that the C1 error is below 100 and ADER is below 2.
8. Press the
ENTER/YES “R”
button and display “
/
a =
”.
Check that the C1 error is below 100 and ADER is below 2
9. Press the
MENU/NO “R”
button, then press the
Z
(MD) button
and take out the disc.
Note:
If the C1 error and ADER are above other than the specified
value at points a (step 8. in the above) or b (step 7. in the above),
the focus bias adjustment may not have been carried out prop-
erly. Adjust perform the beginning again.
16. AUTO GAIN CONTROL OUTPUT LEVEL
ADJUSTMENT
Be sure to perform this adjustment when the optical pick-up is
replaced.
If the adjustment results becomes “Adjust NG!”, the optical pick-
up may be faulty or the servo system circuits may be abnormal.
16-1. CD Auto Gain Control Output Level Adjustment
Procedure:
1. Load the check disc (TDYS-1).
2. Press the
. m
“R”
or
M >
“R”
button to display “AG
Set (CD)” (C11).
3. When the
ENTER/YES “R”
button is pressed, the adjustment
will be performed automatically.
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (CD)” (C11).
4. Press the
Z
(MD) button and take out the check disc.
16-2. MO Auto Gain Control Output Level Adjustment
Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Press the
.
“R”
or
>
“R”
button to display “AG Set (MO)”
(C10).
3. When the
ENTER/YES “R”
button is pressed, the adjustment
will be performed automatically.
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (MO)” (C10).
4. Press the
Z
(MD) button and take out the test disc.
Содержание HCD-CP500K
Страница 7: ...7 HCD CP500K CP500MD SERVICE POSITION OF THE TAPE MECHANISM DECK Tape mechanism deck CN301 CN303 ...
Страница 39: ...39 HCD CP500K CP500MD MEMO ...
Страница 47: ...HCD CP500K CP500MD 47 47 7 4 SCHEMATIC DIAGRAM CD BOARD Page 52 ...
Страница 49: ...HCD CP500K CP500MD 49 49 7 6 SCHEMATIC DIAGRAM BD BOARD 1 2 Page 50 Page 50 Page 50 ...
Страница 50: ...HCD CP500K CP500MD 50 50 7 7 SCHEMATIC DIAGRAM BD BOARD 2 2 Page 49 Page 49 Page 49 Page 57 Page 57 ...
Страница 55: ...HCD CP500K CP500MD 55 55 7 12 SCHEMATIC DIAGRAM TC BOARD IC B D Page 52 ...
Страница 57: ...HCD CP500K CP500MD 57 57 7 14 SCHEMATIC DIAGRAM DIGITAL BOARD IC B D IC B D IC B D Page 50 Page 50 Page 52 ...
Страница 59: ...HCD CP500K CP500MD 59 59 7 16 SCHEMATIC DIAGRAM CONTROL SECTION Page 53 Page 52 Page 52 ...
Страница 93: ...93 HCD CP500K CP500MD MEMO ...