35
HCD-CP500K/CP500MD
6. Press the
.
“R”
or
>
“R”
button so that the reading
of the laser power meter becomes the specified value, press the
ENTER/YES “R”
button to save it.
Note:
Do not perform the emission with 7.0 mW more than 15 seconds
continuously.
7. Then, press the
.
“R”
or
>
“R”
button to display
“LDPWR CHECK” (C13).
8. Press the
ENTER/YES “R”
button once to display “LD 0.9mW$
”. Check that the reading of the laser power meter matches
with the specified value as described in the following table.
9. Press the
ENTER/YES “R”
button once more to display “LD
7.0mW$
”. Check that the reading the laser power meter and
digital voltmeter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value:
Laser power meter reading :
Digital voltmeter reading
: Value on the optical pick-up label
±
10%
10. Press the
MENU/NO “R”
button to display “LDPWR CHECK”
(C13) and stop the laser emission.
(The
MENU/NO “R”
button is effective at all times to stop the
laser emission)
11. Press the
.
“R”
or
>
“R”
button to display “Iop Write”
(C05).
12. Press the
ENTER/YES “R”
button. When the display becomes
Ref=@@@.@ (@ is an arbitrary number), press the
ENTER/
YES “R”
button to display “Measu=@@@.@” (@ is an arbitrary
number).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Press the
.
“R”
or
>
“R
button.
To select the digit
: Press the
[REC MODE]
button.
14. When the
ENTER/YES “R”
button is pressed, “Complete!” will
be displayed momentarily. The value will be recorded in the non-
volatile memory and the display will become “Iop Write” (C05).
Note:
After step 4, each time the
ENTER/YES “R”
button is pressed, the
display will be switched to “LD 0.7mW$
” and “LD 6.2mW$
Nothing needs to be performed here.
12. TRAVERSE ADJUSTMENT
Connection:
Procedure:
1. Connect an oscilloscope to CN105 pin
4
(TE) and CN105 pin
6
(VC) on the BD (MD) board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Press the
M
“R”
button to move the optical pick-up outside
the pit.
4. Press the
.
“R”
or
>
“R”
button to display “EF MO
ADJUST” (C07).
5. Press the
ENTER/YES “R”
button to display “EFB =
MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Press the
.
“R”
or
>
“R”
button so that the waveform of
the oscilloscope becomes the specified value.
(When the
.
“R”
or
>
“R”
button is pressed, the
of
“EFB=
” changes and the waveform changes) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the waveform
so that the specified value is satisfied as much as possible.
(Read power traverse adjustment)
Traverse Waveform
7. Press the
ENTER/YES “R”
button and save the result of
adjustment to the non-volatile memory (“EFB =
SAVE” will
be displayed for a moment. Then “EFB =
MO-W” will be
displayed).
Note 1:
Data will be erased during MO reading if a recorded disc is
used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the oscilloscope
as shown in the following figure so that it can be seen more
clearly.
KMS260B
20101
H0576
lOP=57.6 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/1 (
Ω
)
(Optical pick-up label)
For details of the method for
checking this value, refer to
“8. Recording and Displaying
the Iop Information”
+
–
oscilloscope
(DC range)
V: 0.1 V/div
H: 10 ms/div
BD (MD) board
CN105 pin
4
(TE)
CN105 pin
6
(VC)
A
B
VC
Specification A = B
11. Iop NV SAVE
Write the reference values in the nonvolatile memory to perform
“Iop compare”. As this involves rewriting the reference values, do
not perform this procedure except when adjusting the laser power
during replacement of the optical pick-up and when replacing the
IC102. Otherwise the optical pick-up check may deteriorate.
Note:
Perform this function with the optical pick-up set at room temperature.
Procedure:
1. Press the
.
“R”
or
>
“R”
button to display “Iop NV Save” (C06).
2. Press the
ENTER/YES “R”
button and display “Iop [stop]”.
3. After the display changes to “Iop =xxsave?”, press the
ENTER/
YES “R”
button.
4. After “Complete!” is displayed momentarily, the display changes
to “Iop 7.0 mW”.
5. After the display changes to “Iop=yysave?”, press the
ENTER/
YES “R”
button.
6. When “Complete!” is displayed, it means that Iop NV saving
has been completed.
+
–
oscilloscope
(DC range)
10 pF
330 k
Ω
CN105 pin
4
(TE)
CN105 pin
6
(VC)
BD (MD) board
The method of identifying the optical pick-up (KMS-260B/260E)
UV adhesive agent
Optical pick-up
(KMS-260B/260E)
Pink
: KMS-260B
White : KMS-260E
UV adhesive agent =
SPECIFIED VALUE
KMS-260B
KMS-260E
6.7 to 7.1 mW
7.2 to 7.3 mW
SPECIFIED VALUE
KMS-260B
KMS-260E
0.85 to 0.91 mW
0.90 to 0.96 mW
SPECIFIED VALUE
KMS-260B
KMS-260E
6.8 to 7.2 mW
7.0 to 7.5 mW
Содержание HCD-CP500K
Страница 7: ...7 HCD CP500K CP500MD SERVICE POSITION OF THE TAPE MECHANISM DECK Tape mechanism deck CN301 CN303 ...
Страница 39: ...39 HCD CP500K CP500MD MEMO ...
Страница 47: ...HCD CP500K CP500MD 47 47 7 4 SCHEMATIC DIAGRAM CD BOARD Page 52 ...
Страница 49: ...HCD CP500K CP500MD 49 49 7 6 SCHEMATIC DIAGRAM BD BOARD 1 2 Page 50 Page 50 Page 50 ...
Страница 50: ...HCD CP500K CP500MD 50 50 7 7 SCHEMATIC DIAGRAM BD BOARD 2 2 Page 49 Page 49 Page 49 Page 57 Page 57 ...
Страница 55: ...HCD CP500K CP500MD 55 55 7 12 SCHEMATIC DIAGRAM TC BOARD IC B D Page 52 ...
Страница 57: ...HCD CP500K CP500MD 57 57 7 14 SCHEMATIC DIAGRAM DIGITAL BOARD IC B D IC B D IC B D Page 50 Page 50 Page 52 ...
Страница 59: ...HCD CP500K CP500MD 59 59 7 16 SCHEMATIC DIAGRAM CONTROL SECTION Page 53 Page 52 Page 52 ...
Страница 93: ...93 HCD CP500K CP500MD MEMO ...