5-14
CCD-TRV107E/TRV108E/TRV208E/TRV408E
3. Flange Back Adjustment
(Using Flange Back Adjustment Chart and Subject
More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
3-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass)
(Luminance: 200 ± 30 lux)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
46 to 55, 58
Note1:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note2:
Make the lens horizontal and perform this adjustment.
Note3:
1/4 CCD model: CCD-TRV408E
1/6 CCD model: CCD-TRV107E/TRV108E/TRV208E
Switch setting:
NIGHT SHOT (Lens block) ............................................ OFF
Adjusting method for 1/4 CCD model:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
86
Write down the data.
3
F
86
00
Set the data and press PAUSE
button.
4
6
01
13
Set the data, and press PAUSE
button.
5
6
01
15
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note4)
7
F
86
Set the data that is written down
at step 2 and press PAUSE button.
Note4:
The adjustment data will be automatically input to page: F, address:
46 to 55, 58.
Adjusting method for 1/6 CCD model:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button.
3
6
01
15
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
46 to 55, 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
Turn off the power and turn on
again.
3
Perform “Flange Back Adjustment
(2)”
3-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
46 to 55, 58
Note1:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note2:
Make the lens horizontal and perform this adjustment.
Switch setting:
NIGHT SHOT (Lens block) ............................................ OFF
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method for 1/4 CCD model:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
86
Write down the data.
3
F
86
00
Set the data and press PAUSE button.
4
6
01
13
Set the data, and press PAUSE button.
5
Place a ND filter on the lens so
that the optimum image is obtain.
6
6
01
29
Set the data, and press PAUSE button.
7
6
02
Check that the data changes to
“01”. (Note3)
8
F
86
Set the data that is written down
at step 2 and press PAUSE button.
Note3:
The adjustment data will be automatically input to page: F, address:
46 to 55, 58.
Adjusting method for 1/6 CCD model:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE button.
3
Place a ND filter on the lens so
that the optimum image is obtain.
4
6
01
29
Set the data, and press PAUSE button.
5
6
02
Check that the data changes to
“01”. (Note3)
Note3:
The adjustment data will be automatically input to page: F, address:
46 to 55, 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE button.
2
0
01
00
Set the data.
3
Turn off the power and turn on again.
4
Perform “Flange Back Check”.
RadarW
RadarW
RadarW
RadarW
RadarW
Содержание Handycam Vision CCD-TRV107E
Страница 52: ...SECTION 3 BLOCK DIAGRAMS 3 1 CCD TRV107E TRV108E TRV208E TRV408E ...
Страница 100: ...5 1 CCD TRV107E TRV108E TRV208E TRV408E SECTION 5 ADJUSTMENTS ...
Страница 169: ...CCD TRV107E TRV108E TRV208E TRV408E 216 Sony EMCS Co 2001L1600 1 2001 12 Published by DI Customer Center 9 929 927 11 ...
Страница 170: ...Revision History Ver 1 0 Date 2001 12 History Official Release Contents S M Rev issued 992992711 pdf Reverse ...