31
Menu Operation
Ad
ju
stme
n
t
9
Press the EXEC button to make a printout of the
pattern print.
The unit starts the printing of the tone pattern.
When the density pattern printing is completed, the
following screen appears on the LCD panel.
(If the screen does not appear, press the
G
button to
return to step 4, press the
F
or
f
button to move the
cursor to “Point95%”, and then press the
g
button.)
While checking the density pattern print, perform the
following steps to adjust the low tone and high tone.
10
Adjust the low tone.
Select the desired lightest area of the image.
1
Select the number of the desired low tone area
(light area data 95%).
The low tone range is between 01 and 49 (10, 20,
30 and 40 are skipped).
Chart of the low tone range
2
Display the selected number by pressing the
F
or
f
button.
To reset to the default setting of the low tone
range
Display 25.
11
Press the EXEC button.
The low tone setting is stored, and the following
screen appears on the LCD panel.
(If the screen does not appear, press the
G
button to
return to step 4, press the
F
or
f
button to move the
cursor to “Point5%”, and then press the
g
button.)
12
Adjust the high tone.
Select the desired darkest area of the image.
1
Select the number of the desired high tone area
(dark area data 5%).
The high tone range is between 51 and 99 (60, 70,
80 and 90 are skipped).
The next lightest part
The lightest part
The tone of
the border of
each box on
the chart can
be changed to
that of the
borders
above or
below it on
the chart.
The tone of the center of each box on the chart can
be changed to that of the boxes to the right or left of
it as shown in the chart.