SEL85F14GM (FE 1.4 / 85 GM) (FE 85mm F1.4 GM)
4-1
4. ADJUSTMENTS
Note:
Perform adjustments after service by referring to this chapter.
4-1. PREPARATIONS (BEFORE ADJUSTMENT)
4-1-1. Adjustment Items after Replacing Parts
When replacing main parts and boards, adjust the items indicated by
z
in the following table.
Note:
Do not adjust the items indicated by ×.
Replacement Parts
Adjustment Items
Service Exclusive
Optics Block
1st Group
Assy (9139)
3rd Group
Assy (9139)
Stator Assy
B
GD Lens
Barrel Assy
(9139)
Iris
(A
TS-40B-F1)
CL-1041 Board
(Service)
Rear Barrel
Assy (9139)
Mount Assy
(9139)
Iris Ring
Assy
(9139)
Focus Ring
(9139)
Outer Assy
Service (9139)
Optical Axis Check/Adjustment
×
z
z
z
z
z
z
z
z
z
z
z
Resolving Power Check/Adjustment
z
z
z
z
z
z
z
z
z
z
z
z
Flange Back Check
×
z
z
z
z
z
z
z
z
z
z
z
E-Mount Lens
Adjustment
Lens Device (S)
z
z
z
z
z
z
z
z
z
z
z
z
Lens Device 2 (S)
×
×
×
z
×
×
z
×
×
×
×
×
Flange Back (S)
×
z
z
z
z
z
z
z
z
z
×
z
F Number (S)
×
×
×
×
×
z
×
×
×
×
×
×
Rom Check
z
z
z
z
z
z
z
z
z
z
z
z
Adjustment execute Check
z
z
z
z
z
z
z
z
z
z
z
z
Iris Close
z
z
z
z
z
z
z
z
z
z
z
z
Lens Sleep
z
z
z
z
z
z
z
z
z
z
z
z
4-1-2. Adjustment/Check Order Flowchart
After Replacing Parts
NG
NG
NG
NG
OK
OK
OK
OK
OK
OK
NG
Flange Back (S)
Lens Device (S)
Lens Adjustment Program
E-Mount Lens Adjustment
NG
Replace the Service
Exclusive Optics Block
Lens Device 2 (S)
Flange Back (S)
F Number (S)
Rom Check
Adjustment execute Check
Iris Close
Lens Sleep
Lens Adjustment Program
E-Mount Lens Adjustment
Section 4-6