SEL85F14GM (FE 1.4 / 85 GM) (FE 85mm F1.4 GM)
4-5
4-2-3. Optical Axis Adjustment
1. Remove the Front Ring (9139), Protection Rubber GD (9139) and Filter Screw Barrel Assy (9139) referring to the “2-1. DISASSEMBLY”.
2. Loosen the three screws fixing the GD Lens Barrel Assy (9139).
3. Attach the checking lens to the flange back tester referring to the steps 1 to 3 of “4-2-2. Optical Axis Check”, set the 1000 mm collimator.
4. Adjust (shift) the GD Lens Barrel Assy (9139) so that the ring chart image becomes the center while observing the 1000 mm collimator.
5. Perform the “4-2-2. Optical Axis Check”, make sure that the optical axis of checking lens satisfies the specification.
6. When the specification (reference value) is satisfied, tighten the three screws loosened at Step 2.
7. Apply the adhesive bond (B-10) to the tightened three screws.
8. Apply the adhesive bond (B-110) to the specified locations of the GD Lens Barrel Assy (9139).
Apply the adhesive
bond (B-10)
Apply the adhesive
bond (B-110)
Apply the adhesive
bond (B-10)
Apply the adhesive
bond (B-10)
Apply the adhesive
bond (B-110)
Apply the adhesive
bond (B-110)
Screw
Screw
Screw
GD Lens Barrel Assy (9139)
4-3. RESOLVING POWER CHECK
4-3-1. Photographic Resolving Power Check
Equipments and Tools
• Resolution Check Chart (ILC)
• Camera (General E-mount Interchangeable Lens Digital Camera with Full Size)
• 40 inch LCD monitor (Full HD)
Note:
When checking and adjusting, check the resolution by expanding the photographed image.
Setting of Equipments
1. Set the Shooting Mode of the camera to the Aperture Priority mode and set the f-stop value to the minimum (open).
2. Set the camera at the position where a chart appears in the whole screen. Furthermore, move it to the 100 mm rear from that position.
1125mm x 750mm 3:2 2015.12.15 LENS Gp
0.8
0.6
0.5
0.3
0.3
0.5
0.6
0.8
Checking Method
1. Set to manual focus on status that the “Setting of Equipments” condition.
2. Focus and shoot with self timer.
3. Keep focusing as step 2, change the object distance to the shooting distance position ± 100 mm of step 1, then shoot two times with self timer.
4. Check the three images to see if the resolution of the patterns in four corners meets the standard shown in the below.
1125mm x 750mm 3:2 2015.12.15 LENS Gp
0.8
0.6
0.5
0.3
0.3
0.5
0.6
0.8
*Check the center circle (red frame) and the other peripheral
circles (blue frame) at the same magnification.
Note:
Check if the circle in the center is resolved clearly. Then, check to ensure the other circles (24 circles) are resolved symmetrically in vertical and horizontal
directions. (A circle and its counterpart on the diametrically opposite side are resolved equally.)
* Use Adobe Photoshop to check the image resolution.