3-39
DSR-2000A/2000AP
3-11. Precautions for use of
Condensation Sensor
Due to the foreign substances adhering to the condensation
sensor chip (see figure below), the sensor fails to measure
the correct value of residence to humidity. This prevents
the unit from functioning properly. If any foreign sub-
stance gets adhered to the chip, replace the condensation
sensor with a new one.
m
.
Do not touch the chip with bare hands.
.
Do not clean the chip with alcohol or other similar
agents.
Connector
1 pin
Leads
Condensation
sensor chip
Bracket
Solders