5-18
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
8. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
3A, 3B
Specified Value
1/6 CCD TYPE S model:
R ratio: 2B80 to 2C80
B ratio: 5E00 to 5F00
1/4 CCD TYPE S model:
R ratio: 2A80 to 2B80
B ratio: 6100 to 6200
1/4 CCD TYPE M model:
R ratio: 2B00 to 2C00
B ratio: 6100 to 6200
Note1:
1/6 CCD TYPE S model: CCD-TRV107/TRV108
1/4 CCD TYPE S model: CCD-TRV608
1/4 CCD TYPE M model: CCD-TRV308/ TRV408
Note2:
After the power is turned on, this adjustment can be done only
once.
Note3:
Perform “Auto White Balance & LV Standard Data Input” before
this adjustment.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
NIGHT SHOT (Lens block) ............................................ OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
LIGHT (FK-2000 block) .................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
0
01
01
Set the data.
3
F
90
Write down the data.
4
F
90
Set the following data, and press
PAUSE button.
2C: 1/6 CCD TYPE S model
2B: 1/4 CCD TYPE S model
2B: 1/4 CCD TYPE M model
5
F
91
Write down the data.
6
F
91
Set the following data, and press
PAUSE button.
00: 1/6 CCD TYPE S model
00: 1/4 CCD TYPE S model
80: 1/4 CCD TYPE M model
7
F
92
Write down the data.
8
F
92
Set the following data, and press
PAUSE button.
5E: 1/6 CCD TYPE S model
61: 1/4 CCD TYPE S model
61: 1/4 CCD TYPE M model
9
F
93
Write down the data.
10
F
93
80
Set the data, and press PAUSE
button.
11
6
01
A7
Set the data, and press PAUSE
button.
12
Wait for 2 sec.
13
6
01
A5
Set the data, and press PAUSE
button.
14
6
02
Check that the data changes to
“01”. (Note5)
15
6
01
3F
Set the data, and press PAUSE
button.
16
0
03
04
Set the data.
17
1
Check that the display data (Note4)
satisfies the R ratio specified value.
18
0
03
05
Set the data.
19
1
Check that the display data (Note4)
satisfies the B ratio specified value.
Note5:
The adjustment data will be automatically input to page: F, address:
3A, 3B.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
F
90
Set the data that is written down
at step 3, and press PAUSE button.
3
F
91
Set the data that is written down
at step 5, and press PAUSE button.
4
F
92
Set the data that is written down
at step 7, and press PAUSE button.
5
F
93
Set the data that is written down
at step 9, and press PAUSE button.
6
0
03
00
Set the data.
7
0
01
00
Set the data.