5-27
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
6. V-COM Adjustment (PD-156 board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
7
Adjustment Address
45
Specified Value
The brightness difference between the
section A and section B is minimum.
Note:
This adjustment should be carried out upon completion of the
following adjustments.
RGB AMP Adjustment
Contrast Adjustment
COM AMP Adjustment
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
45
Change the data so that the
brightness of the section A and
that of the section B is equal.
3
7
45
Subtract 8 from the data.
4
7
45
Press PAUSE button.
5
0
01
00
Set the data.
7. White Balance Adjustment (PD-156 board)
Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
7
Adjustment Address
49, 4A
Specified Value
The LCD screen should not be colored.
Note:
Check the white balance only when replacing the following parts. If
necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5501
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
49
60
Set the data, and press PAUSE
button.
3
7
4A
65
Set the data, and press PAUSE
button.
4
7
49
Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
5
7
49
Change the data so that the LCD
screen is not colored.
6
7
49
Press PAUSE button.
7
7
4A
Change the data so that the LCD
screen is not colored.
8
7
4A
Press PAUSE button.
9
7
4A
If the LCD screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
Fig. 5-1-19.
A
A
A
A
B
B
B
B