Confidential
MANUAL
51(51)
Document number
Revision
7/198 17-LXE 108 566 Uen
A
Note: Any hard copy of this document is for reference only.
Due to template and application dependencies the header and footer may fail to display correct data. It is the
responsibility of the user to ensure that they have a correct and valid version. Any outdated hard copy is invalid and must be removed from possible use.
7 Technical Data
Mechanical specifications
Maximum length:
130.00 mm
Maximum width:
49.50 mm
Maximum thickness:
15.0 mm
Weight:
37.5 g
Power supply voltage, normal
operation
VCC_MAIN / VCC_AUX
Nominal Voltage:
5.00 Volts
Voltage range:
4.50 – 5.50 Volts
Radio specifications
EGSM
GSM
DCS
Frequency range:
TX: 880 – 890
RX: 925 - 935
TX: 890 - 915
RX: 935 - 960
TX: 1710 - 1785
RX: 1805 - 1880
Antenna impedance:
50
Ω
50
Ω
50
Ω
Operational VSWR (Maximum):
2:1 2:1 2:1
Maximum VSWR before damage:
8:1 8:1 8:1
Environmental specifications
Operating temperature range:
-10
°
C to +55
°
C: ETSI TS 151 010-1 VER 4_6_0
-40
°
C to –10
°
C: –3dB degradation on TX output power and
RX sensitivity, also, GM41 will not misuse frequency
spectrum.
+55
°
C to +85
°
C: –3dB degradation on TX output power and
RX sensitivity, also, GM41 will not misuse frequency
spectrum.
Storage temperature range:
-40
0
C to +85
0
C
Maximum relative humidity:
80% at +30
˚
C
Stationary vibration, random
Power spectral density (G
2
/Hz):0.40, 0.1, 0.1, 0.002, 0.002,
Frequency (Hz):10, 20, 100, 800, 1000
120 min per/axis, 4.3Grms
Non-stationary vibration, including shock
•
Shock response spectrum I, peak acceleration:
- 3 shocks in each axis and direction: 20G, 11 ms
Free fall transportation:
1.0 m
Low air pressure/high air pressure:
70 kPa / 106 kPa
Table 29: Technical Data