Confidential
USERS MANUAL
130(158)
Document number
Revision
1/198 17-4/FCP 101 3045 Uen
D
5.2.12
AT*EDTXS
Read Transmit Buffer Status
Description
Syntax
Possible responses
Reads the transmit status
AT*EDTXS
*EDTXS: 0
*EDTXS: 1, <timeout>
OK
This command reports the current state of the dialed digit buffer. The reported values are as follows:
*EDTXS: 0
there is no transmission pending
*EDTXS: 1, <timeout> a pending transmission will occur after the displayed timeout
The AT*EDTXS command will return ERROR if the feature required for this function is not enabled. Feature
required for this command:
o
Aeris Microburst
5.2.13 AT*EDSERV
MicroBurst
Service
Search
Note:
This command has no function in the current version of CM52. It is retained for reference and
for possible future use.
Description
Syntax
Possible responses
Sets the service search mode
and scan time interval.
AT*EDSERV=<search>,
<scan_time><CR>
OK
Displays the service search
mode and scan time interval.
AT*EDSERV?<CR>
*EDSERV: <search>, <scan_time>,<SID>
This command enables/disables the automatic A/B service search algorithm and sets the time interval for
determining if micro burst service is available. The automatic service search does not have any effect unless
the module is configured to look at multiple bands.
When enabling automatic service search mode it is important to set the home SID either to 0 or to a SID where
service is known to be available. This is necessary because if a module detects broadcast SID that matches
the configured SID then it will lock on that SID and not switch bands.
The AT*EDSERV command can be used to cause an immediate A/B switchover by entering
AT*EDSERV=0,0. In this case, the parameter values are not altered. However, the implied timeout value of 0
triggers an immediate changeover.
Parameter
Description
<search>
0
OFF. The automatic MicroBurst A/B service search is disabled.
1
ON. The automatic MicroBurst A/B service search is enabled.
<scan_time> 30..1800
The scan time in seconds the module waits for the detection of the MicroBurst
service before switching to the alternate band.
Default value is 900.
0 indicates an immediate A/B switchover.
<SID> 2..32767
The system ID (SID) of the service provider
The AT*EDSERV command will return ERROR if the feature required for this function is not enabled. Feature
required for this command:
o
Aeris Microburst