3. Functional description
3.1 Supply and safety
The Superstatic 470/479 must be operated with a mains power voltage of 230/90 VAC or 24 V
AC/DC.
A battery supply is not permitted.
Please respect the following notes.
3.1.1 Power supply modules
The mains power module 230/90 VAC – 45/60 Hz is to be protected by an (inert) 1AT fuse.
Electrical connection of the power supply modules
The electrical connection is to be established by a qualified person in compliance with the valid
standards and having regard to local safety requirements. The mains power line is to be laid in
such a way that no hot parts (pipes etc. above 80 °C) may damage its insulation. The electrical
connections must not come into contact with water.
3.1.2 Safety instructions
The Superstatic 470/479 has been manufactured and tested in compliance with safety standard
EN60950 and was perfectly safe at the time of dispatch from the factory. To maintain that condition
and ensure safe operation of the appliance the user must comply with the instructions set out in
this document. When opening covers or removing components parts which carry voltage may be
exposed. All interventions and repairs must therefore be performed by a specially trained and
authorised professional. If the housing and/or the connection cable are damaged the power supply
module must be disconnected and secured against accidental re-starting. In general, an installation
situation with above average heat accumulation must be avoided. Above average heat
accumulation is prejudicial to the service life of the electronic components.
For protection against damage and dirt, the packaging should not be removed until immediately
before installation.
For cleaning purposes use only a cloth moistened with water. Do not use cleaning fluids or
solvents.
The connection cables must not be secured to the pipe and under no circumstances may they be
insulated.
0470P004 Manual Superstatic 470 SPF 02-03-2015
7