All the parameterization and read -out functions of the Superstatic 470/479 computing unit are
identical to the functions of the Supercal 531/Prog531 computing unit.
Note: The Firmware version of the Superstatic 470/479 computing unit must be higher than
V10.0.0.0.
The arrows on the LCD display symbolize the outgoing/incoming communication.
2.4 Differences between SPF1, SPF2, SPF3
Three different performance factors can be measured and displayed using the Superstatic
470/479.
The SPF1 value displays the performance factor of the heat pump over a particular period of time.
The SPF1 can be equated with a seasonal performance factor (COPA). The value of the previous
period is stored and can be displayed.
The value SPF2 shows the performance factor of the heat pump since its initial commissioning.
The SPF2 is never reset.
The SPF3 value shows the performance factor of the heat pump in an event period of one day.
The SPF3 is reset daily at midnight. An overview of the past 31 days can be shown on the display.
Each current meter of the heat pump can be connected to the heat pump module to enable the
electrical energy absorbed by the whole facility to be determined.
Example of configuration:
Environmental heat
Heat pump
Useful energy
and hot water
Umwälz-
pumpe
Circulating
pump
Losses
Electric
meter
Electric
meter
Electric
meter
Electric
meter
Digital
inputs
PAC
Module
Superstatic 470/479
1 2 3 4 5 6 7
Communication sortante
Communication entrante
0470P004 Manual Superstatic 470 SPF 02-03-2015