GB
35
Installation & Operating Manual 12/2013
13 Decommissioning
cAUtIon!
Risk of injury from water-glykol mixture!
Water-glykol mixtures can be harmful to health and flammable.
X
Avoid open flames and sparking.
X
Secure discharge hose in container against slipping out.
X
Disconnect styring on the stratified charging module from mains.
X
Drain water-glykol mixture via filling forward flow into a suitable container and store or dispose
of in accordance with locally applicable regulations.
X
Shut off backup circuit forward flow and return flow.
X
Drain backup circuit
14 Dismounting
D
Stratified charging module shut down
X
Disconnect stratified charging module at shut-off ball valves.
cAUtIon!
Risk of injury from falling stratified charging module!
Weight of stratified charging module without water content:
SLM120/200/300HE approx. 90/115/120 kg (specification)
X
Dismount stratified charging module with suitable lifting gear.
X
Detach screws at the baseplate. Retain with suitable lifting means during the process.
X
Take stratified charging module off the wall and set down at a suitable position. Cover if appli-
cable.
The stratified charging module has been dismantled.
15 cleaning and care
X
Clean and care for styring according to data in third-party manual.
X
Do not clean cover (optional) with aggressive cleaning agents.
X
Keep cover (optional) clean and regularly remove coarse dirt, dust and moisture.
16 Disposal
Stratified charging module contains components subject to the European ROHS Directive
2002/95/EC on the restriction of the use of certain hazardous substances in electrical and elect-
ronic equipment.
X
Do not dispose of the system and components as household waste.
X
Only dispose of system and components using an appropriate collection point.