![Sonnenkraft SLM120HE Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/sonnenkraft/slm120he/slm120he_manual_1321805027.webp)
GB
27
Installation & Operating Manual 12/2013
X
Ensure that the installation location is near the backup storage tank.
X
Ensure that the space is clean and frost-free.
X
Ensure that a mains connection is available:
Positioned to the right of the stratified charging module
At most 1.5 m away from the stratified charging module
7.2
Mounting stratified charging module on a wall
cAUtIon!
Risk of injury from falling stratified charging module!
Weight of stratified charging module without water content:
SLM120/200/300HE approx. 90/115/120 kg
X
Lift stratified charging module out of packaging with suitable lifting gear.
X
Lay down stratified charging module with baseplate on a flat surface.
X
Screw on and remove cover (optional) on the side.
notE!
Damage to stratified charging module from falling stratified charge module!
X
If mounting on wall, use all 4 mounting points on the wall.
X
Use supplied mounting material.
X
Drill holes for all 4 mounting points.
Dimensions: see graphic and data sheet.
880 mm
625 mm
880 mm
Abb. 2 Mounting points
X
Insert supplied screw anchors into holes.
Use a different suitable type of anchor for different masonry if necessary.
X
Screw the 4 supplied panel screws into the drilled holes and tighten them.
X
Position stratified charging module on the wall with suitable lifting gear and hold tightly in place.
X
Have panel screws tightened by a second person.
The stratified charging module is mounted.