4
Copyright © 2014 Somfy SAS. All rights reserved.
EN
Rollixo RTS
4.3 Adding remote controls
This operation must be carried out close to the receiver.
This operation involves adding a remote control to your installation by copying
a remote control already used on your installation.
Remote control "A" = "source" remote control already memorised
Remote control “B” = “target” remote control to be added
> 2 or 4-button remote control
B
A
A
2s
[1].
Press the outer left and right buttons on the previously memorised remote
FRQWURO$VLPXOWDQHRXVO\XQWLOWKHUHGLQGLFDWRUOLJKWÀDVKHV
[2].
Press the remote control button A which controls your roller garage door
for two seconds.
[3].
Press the button on new remote control B which will control your roller
garage door.
> 3-button remote control
A
B
2s
< 1s
5 - OPERATING DIAGNOSTICS
The indicator lights on the front of the Rollixo receiver notify the user of the
installation's status.
3
4
2
1
Prog
STOP
Motor
Fall protection
Safety edge
Safety edge
transmitter batteries
Photoelectric
cells
Indicator light status
Meaning
Off
Functional installation
5DSLGÀDVKLQJ
Deactivation/activation in progress
Permanently lit
Installation fault/failure
Indicator light status
Prog
Motor
Diagnostics
Activated motor thermal protection
Consequences
No movement possible
Actions
Wait around 10 minutes.
Indicator light status
Prog
Radio safety
edge
Diagnostics
Radio interference on the safety edge
transmitter
Consequences
Opening and stopping ok
Closing by pressing and holding down
the button within sight of the door
Actions
If a powerful radio system is present on
the site (infrared detector, TV transmitter,
etc.) and is transmitting on the same
frequency, the receiver will wait for the
transmission to end to before controlling
the door again.
Diagnostics
Safety edge transmitter low battery
indication.
Consequences
Opening ok
Closing by pressing and holding down
the button within sight of the door
Actions
If the fault persists, replace the safety
edge transmitter batteries.
Diagnostics
Obstacle detection
Consequences
Remove the obstacle by automatic partial
opening
Actions
Check that no obstacle is causing the
safety edge to detect.
Photoelectric
cells
Diagnostics
Cell fault
Consequences
Opening ok
Closing by pressing and holding down
the button within sight of the door
Actions
Check that no obstacle is cutting across
the cell beam
Diagnostics
Obstacle detection
Consequences
Remove the obstacle by full automatic
opening
Actions
Check that no obstacle is cutting across
the cell beam.
If a fault is still present on your installation, please contact your installer.