Copyright © 2010 Somfy SAS. All rights reserved.
Pergola sc io
44
EN
To activate this function:
1) Put the blind in the middle position.
Briefly press the "my" and Down buttons simultaneously,
2)
then immediately afterwards press and hold the "my"
and Down buttons until the blind moves briefly.
The motor is in programming mode for just
10 seconds.
Adjust the fabric tension using the Up or Down buttons.
3)
To increase the fabric tension, press the Up button until
-
the blind moves slowly: the fabric tension has switched
to "high".
To decrease the fabric tension, press the Down button until the blind moves slowly:
-
the fabric
tension has switched to "low".
Press the "my" button until the blind moves briefly: the new fabric tension has been programmed.
4)
7.4.2. "Closing force" function on cassette blinds only
This function enables the closing force of the awning cassette to be increased or decreased over 3
levels (high/medium/low).
The motor's default factory setting is the low level.
For safety reasons, this function can only be accessed via the Somfy io control point in 3 scenarios:
After validation of the settings and before programming the first Somfy io control point.
•
After programming the first Somfy io control point and for the next 4 cycles.
•
After a power cut, and for the next 4 cycles.
•
To activate this function:
1) Put the blind in the middle position.
Briefly press the "my" and Up buttons simultaneously,
2)
then immediately afterwards press and hold the "my" and
Up buttons until the awning moves.
The motor is in programming mode for just
10 seconds.
Adjust the closing force using the Up or Down buttons.
3)
To increase the closing force, press the Up button until
-
the blind moves slowly: the cassette awning closing force
is increased to the upper threshold.
To decrease the closing force, press the Down button until the blind moves slowly:
-
the cassette
awning closing force is decreased to the lower threshold.
Press the "my" button until the awning moves: the new closing force has been programmed.
4)
or
or
0.5 s
5 s
1
2
3
4
or
or
0.5 s
5 s
1
2
3
4
8. TIPS AND RECOMMENDATIONS
8.1. Questions about the Pergola sc io?
Observations
Possible causes
Solutions
The blind does not
operate.
The wiring is incorrect.
Check the wiring and modify it if necessary.
The motor is hot.
Wait until the motor cools down.
An incorrect cable has been used.
Check the cable and ensure it has 3
strands.
The Somfy io control point battery is
low.
Check whether the battery is weak and
replace it if necessary.
The control point is not compatible.
Check for compatibility and replace the
control point if necessary.
The Somfy io control point used has
not been programmed into the motor.
Use a programmed control point or program
this control point.
The blind stops
too soon.
The crown is incorrectly positioned.
Fit the crown correctly.
The end limits have been incorrectly
set.
Readjust the end limits.
Markizy.by