Copyright © 2010 Somfy SAS. All rights reserved.
Pergola sc io
40
EN
The guide only describes commissioning using a Situo io type Somfy io local control point. For
commissioning using any other io control point, refer to the corresponding guide.
5.1. Identifying setting steps already completed
Only one motor should be powered at a time.
Switch on the power and follow procedure "a" or "b",
according to the blind's reaction:
a
The blind moves briefly
The end limits are set and no Somfy io control point
has been programmed.
Go to the section"
Programming the first Somfy io local
control point
".
or
b
The blind does not move
Press the Up or Down button, and follow procedure "c"
or "d" according to the blind's reaction:
c
The blind still does not move
The end limits are not set and no Somfy io control
point has been programmed.
Go to the section "
Pre-programming the Somfy io
local control point
".
or
d
The blind is fully raised or lowered
The end limits are set and the Somfy io control point
has been programmed.
Go to the section "
Operation
".
5.2. Pre-programming the Somfy io local control point
Press the Up and Down buttons simultaneously: the
-
blind will move briefly; the Somfy io local control point
has been pre-programmed into the motor.
5.3. Checking the motor's direction of rotation
Press the Up button:
1)
If the blind is raised, the direction of rotation is correct:
a)
go to the section "
Setting the end limits
".
If the blind is lowered, the direction of rotation is
b)
incorrect: press the "my" button until the blind moves
briefly; the direction of rotation has been modified.
Press the Up button to check the direction of rotation.
2)
ON
Programming the
1st Somfy io local
control point.
c
or
d
Pre-programming the
Somfy io local control
point.
Operation.
a
b
Setting the end
limits
2 s
1
2
5. COMMISSIONING
Markizy.by