Commissioning and standard use
21
EN
- EXAVIA installation and operating guide - SOMFY
EN
2
6
STOP
•
Press button 1 on the remote control again
to stop the gate leaf in the desired opening
position.
•
If required, to fine-tune the opening position
of the gate leaf, open the flap at the end of
the cylinder then screw it in or unscrew it to
obtain the desired opening angle (see
2
).
7
1
2
Do not remove the screws from the stop.
Position the opening stop (
1
) in contact with
the cylinder knob (
2
) then tighten the stop
using a 10 mm offset wrench.
8
Press button 1 on the remote control to close
the gate completely. The leaves close one
aer the other.
9
Clip the end stop covers.
Check before proceeding to the next step
Have you set the position of the opening stop on each motor?
2.3 Gate travel auto-programming
Check that the installation is switched on: the indicator light flashes (twice).
Case 1: First commissioning of your motorisation
Press button 1 on the remote control to initiate a COMPLETE opening motion of the gate. When
the gate is completely open, press button 1 on the remote control again to launch a FULL closing
movement of the gate.
When the gate is completely closed, the indicator light on the control unit should be
CONTINUOUSLY LIT.
Case 2: You have just deleted the settings
Launch 4 full gate opening and closing movements.
Upon completion of the 4 movements, indicator light on the control unit must be
CONTINUOUSLY LIT.
The gate movements must not be interrupted (complete opening/closing).
If they are interrupted, programming will resume the next time the opening command is issued.
If the indicator light flashes, relaunch auto-programming of the gate travel (4 complete opening and closing movements).
If the indicator light continues to flash, refer to “Diagnostics”, page 32.
If the gate re-opens at the end of the closing movement, loosen and offset the gate leaf brackets slightly towards the centre of the gate.
WARNING
Once installation is complete, it is essential to check that the obstacle detection system complies with Annex A of the standard EN 12 453.
1