Presentation of the control electronics
No.
Designation
Function
A
Button
Reactivation of the control electronics
B
RADIO indicator
light
Lights up each time the control electronics receive a
radio command
C
Indicator light
Lights up during activation/deactivation of the
pedestrian opening
D
Indicator light
On
automatic closing of the gate is activated
Off
automatic closing of the gate is not
activated
Flashing
the "automatic closing" parameter is
selected
E
Indicator light P1
Not used
F
RESET indicator
light
On
the settings alone or the settings and the
radio control points are deleted
Flashing
the settings and radio control points
deletion function is selected
G
Indicator light
On
the motorisation functions correctly - the
control electronics are reactivated
Off
the motorisation functions correctly - the
control electronics are in standby
Flashing
see “Diagnostics”, page 32
Prerequisites for installation
Pre-installation checks
Gate
Your gate is in good condition: it opens and closes normally with ease.
It remains horizontal throughout its travel. It opens inwards towards your property.
Renfort
Patte de
fixation
Reinforcements
The motors must be secured to the
horizontal reinforcements of the gate
leaves, which should ideally be positioned
1/3 up the gate.
If there are no reinforcements, use metal
reinforcement plates approximately
4 mm thick.
Closing stops on the ground
When closing, the gate travel must be
defined by stops secured firmly to the
ground.
The opening stops are integrated into the
motor (see “Adjusting the opening stop”,
page 20).
Mechanical lock
If the gate Sis fitted with a mechanical
lock, this must be removed.
Pillars
The pillars should have a robust structure and be at least 21 cm wide. If not, adjustments to the pillar may be necessary to ensure correct
and solid mounting.
30s
RADIO
P1
RESET
A
B
G
F
E
D
C
Mounting bracket Reinforcement