Advanced parameter settings
26
EN
- EXAVIA installation and operating guide - SOMFY
EN
4
4.2 Automatic closing
Automatic closing operation
Press button 1 on the remote control to open the gate.
The gate closes again aer 30 seconds or 5 seconds if the photoelectric cells detect a passage.
The automatic closing can be interrupted by pressing button 1 on the remote control. To then close the gate, press button 1 on the remote
control again.
Activating automatic closing
Automatic closing can only be activated if the photoelectric cells are connected and recognised by the motor's control electronics.
1
2
3
>2s
Once step 3 has been
carried out, you can
carry out the following
steps remotely
(without placing the
remote control on the
target).
Press the
button on the
control electronics for 2
seconds.
The indicator light comes
on.
Position the remote control on the
control electronics target.
Keep button 1 of
the remote control
depressed until the
indicator light
flashes.
4
5
x2
Keep button 2 on the remote control depressed until the indicator light
goes out and is then lit constantly.
When you release button 2, indicator light
flashes;
press button 1 on the remote control twice.
The indicator light
remains lit.
Automatic closing is activated.