VENTILATION
90-1854
If not using the dehumidifier
to bring in outdoor air,
press MODE to go to
ZONE screen selections.
90-1854
If using the dehumidifier
for ventilation, Enable and
press MODE to select
TIMED or AUTO.
90-1854
If ventilating based on time
only (no outdoor temperature
restrictions), press MODE
at the VENT TIMED screen
to go to ventilation time
selection screen.
If ventilating with outdoor temperature restrictions, use the
UP arrow to go from VENT TIMED to VENT AUTO –B and
then the UP/DOWN arrows to select the desired ventilation
mode, B, C, or D. Press MODE to go to the ventilation time
selection screen.
90-1854
Vent-Auto-B:
Ventilation
prevented when outdoor
temperature is below 0°F
and above 100°F. Between
0°F – 20°F ventilation
is only allowed during a
HVAC heat call.
90-1854
Vent-Auto-C:
Ventilation
prevented when outdoor
temperature is below 0°F
and above 100°F.
90-1854
Vent-Auto-D:
Ventilation
prevented when outdoor
temperature is below 0°F
and above 90°F. Between
0°F – 40°F ventilation
is only allowed during a
HVAC heat call.
Vent-Auto-B, -C, -D
modes apply outdoor temperature
limits and require an outdoor temperature sensor to be
installed.
90-1854
Press the UP or DOWN
arrows to adjust the
ventilation time per hour
from 0 to 60 minutes.
After selecting time, press
MODE to go to the ZONE
screen selections.
System Set-up and Checkout
If dehumidifier installation does not include ventilation or
zoning and will not be wired to an external control, remote
control or the HVAC system, proceed to
INSTALLER TEST
MODE
section on page 14.
1.
Check all wiring.
2.
Make sure the wire access cover has been snapped
back onto the on-board control.
3.
Plug unit in and turn power switch to ON.
4.
The on-board control screen should display OFF.
90-1854
NOTE:
If the display backlight is not on, the first button
press (any button) will only turn on the backlight. Press
the button a second time to achieve function.
5.
Hold the MODE button on the on-board control for 3
seconds to enter the Installer Set-up Menu.
6.
Navigate through the following screens to set up the
dehumidifier for the installed application.
Use the UP or DOWN arrows to select items and use
MODE to switch to the next set-up option. To exit installer
set-up, all options must be scrolled through using the
MODE button.
7.
After the installer set up options have been completed,
DONE will blink for 3 seconds and the control will return
to the OFF screen.
90-1854
90-1854
REMOTE CONTROL –
CRAWL SPACE/SEALED ATTIC
90-1854
If not installing in a crawl
space or sealed attic with
Y6456 remote control,
press MODE to go to VENT
screen selections
90-1854
If installing in a crawl space
or sealed attic with remote
control, Enable and press
MODE. The installer set-up
is complete, proceed to
INSTALLER TEST MODE
section on page 14.
12