Clean the heat sink with compressed air or a soft brush. Do not use 

aggressive chemicals, cleaning solvents or strong detergents.   

For proper function and long service life, ensure free air circulation around the 

heat sink. 

 

13 Recycling and disposal 

Dispose of the packaging and replaced parts according to the 

rules applicable in the country where the device is installed. 

Do not dispose the ASW inverter with normal domestic waste. 

 

 

 

14 EU Declaration of Conformity 

within the scope of the EU directives 

• Electromagnetic compatibility 2014/30/EU (L 96/79-106, March 29, 

2014) (EMC). 

• Low Voltage Directive 2014/35/EU (L 96/357-374, March 29, 2014)(LVD). 

• Radio Equipment Directive 2014/53/EU (L 153/62-106. May 22. 2014) (RED) 

AISWEI Technology (Shanghai) Co., Ltd. confirms herewith that the inverters 

described in this manual are in compliance with the fundamental requirements 

and other relevant provisions of the above mentioned directives.   

The entire EU Declaration of Conformity can be found at 

www.solplanet.net

 

 

 

 

 

 

Do not dispose of the product together with the household waste but in 

accordance with the disposal regulations for electronic waste applicable at 

the installation site. 

Содержание ASW S Series

Страница 1: ......

Страница 2: ...safety information 7 2 3 Symbols on the label 9 3 Unpacking 10 3 1 Scope of delivery 10 3 2 Checking for transport damage 11 4 Mounting 11 4 1 Ambient conditions 11 4 2 Selecting the mounting locatio...

Страница 3: ...1 RS485 cable connection 31 5 6 2 Smart meter cable connection 32 5 6 3 WiFi 4G stick connection 33 6 Communication 34 6 1 System monitoring via WLAN 4G 34 6 2 Active power control with Smart meter 35...

Страница 4: ...t data 45 10 3 General data 47 10 4 Safety regulations 48 10 5 Tools and torque 49 11 Troubleshooting 50 12 Maintenance 52 12 1 Cleaning the contacts of the DC switch 52 12 2 Cleaning the heat sink 52...

Страница 5: ...5000 S A ASW6000 S ASW6000 S A ASW8000 S ASW8000 S A ASW10000 S ASW10000 S A Observe all documentation that accompanies the inverter Keep them in a convenient place and available at all times 1 3 Targ...

Страница 6: ...h this document and all safety information 1 4 Symbols used in this manual Safety instructions will be highlighted with the following symbols DANGER indicates a hazardous situation which if not be avo...

Страница 7: ...en the PV modules are exposed to sunlight a DC voltage is supplied to the inverter 6 When designing the PV system ensure that the values comply with the permitted operating range of all components at...

Страница 8: ...f the inverter Touching the DC conductors or the live components can lead to lethal electric shocks If you disconnect the DC connectors from the inverter under load an electric arc may occur leading t...

Страница 9: ...tive surfaces so that there is continuous conduction Risk of burns due to hot enclosure parts Some parts of the enclosure can get hot during operation During operation do not touch any parts other tha...

Страница 10: ...ing operation Avoid contact during operation WEEE designation Do not dispose of the product together with the household waste but in accordance with the disposal regulations for electronic waste appli...

Страница 11: ...iption Quantity A Inverter 1 piece B Wall mounting bracket 1 piece C Wall anchors and hexagon bolts 3 M5 screw 2 1 set D DC connector 3 pairs E AC Plug connector 1 piece F WiFi stick 1 piece G RS 485...

Страница 12: ...the inverter in areas where it cannot be touched inadvertently 3 Ensure good access to the inverter for installation and possible service 4 Make sure that heat can dissipate observe the following min...

Страница 13: ...board and similar materials are not recommended due to audible vibrations when in use 10 Do not put any objects on the inverter 11 Do not cover the inverter 4 2 Selecting the mounting location Danger...

Страница 14: ...lay 5 The electrical connection area must point downwards 4 3 Mounting the inverter with the wall bracket Mounting procedures 1 Use the wall bracket as a drilling template and mark the positions of th...

Страница 15: ...ivered with the inverter 3 Position and hang the inverter onto the wall bracket ensuring the two studs located on the outer ribs of the inverter are slotted into the respective slots in the wall brack...

Страница 16: ...into the lower screw hole on both sides of the inverter anchorage bracket respectively and tighten them If a second protective conductor is required in installation site ground the inverter and secur...

Страница 17: ...ulated cable ends Do not touch the DC conductors Do not touch any live components of the inverter Have the inverter mounted installed and commissioned only by qualified persons with the appropriate sk...

Страница 18: ...le to safely disconnect the open circuit voltage of the PV array plus a safety reserve of 20 Install a DC switch to each PV string to isolate the DC side of the inverter We recommend the following ele...

Страница 19: ...rings C COM Network port with protective cap D Connector for meter E WiFi transmit and Wi Fi signal F Connection point for an additional grounding G AC OUTPUT plug in connector connect the grid 5 4 AC...

Страница 20: ...tion on grounding components Object Description M5 screw Screwdriver type PH2 torque 3Nm Bootlace ferrule Customer provided type M5 Grounding cable Copper conductor cross section 16mm2 In case of oper...

Страница 21: ...y due to electric shock and fire caused by high leakage current The inverter must be reliably grounded in order to protect property and personal safety The PE wire should longer 2 mm than L N during s...

Страница 22: ...or body 6 Connect the AC connector plug to the inverter s AC output terminal 5 4 3 Conditions for the AC connection Cable Requirements The grid connection is established using three conductors L N and...

Страница 23: ...ltage at the feed in point The maximum cable lengths depend on the conductor cross section as follows Conducto r cross section Maximum cable length ASW5000 S ASW5000 S A ASW6000 S ASW6000 S A ASW8000...

Страница 24: ...residual voltage being present at the corresponding cable after disconnection No consumer load should be applied between AC circuit breaker and the inverter The selection of the AC circuit breaker rat...

Страница 25: ...tend to install the inverter between two line conductors If you are uncertain about this contact your grid operator or AISWEI Safety in accordance with IEC 62109 when the grounding conductor monitorin...

Страница 26: ...e scope of delivery The positive connection cables of the PV modules must be equipped with the positive DC connectors The negative connection cables of the PV modules must be equipped with the negativ...

Страница 27: ...on 2 5 mm to 6 mm Qty single wires at least 7 Nominal voltage at least 600V Proceed as follows to assemble each DC connector 1 Strip 12 mm off the cable insulation 2 Lead the stripped cable into the c...

Страница 28: ...f the stranded wires are visible in the chamber of the clamping bracket the cable is correctly positioned Proceed to step 5 If the stranded wires are not visible in the chamber the cable is not correc...

Страница 29: ...rewdriver blade width 3 5mm as following procedure Danger to life due to high voltages on DC conductors When exposed to sunlight the PV array generates dangerous DC voltage which is present in the DC...

Страница 30: ...or must be reassembled The DC cable must always have the same polarity as the DC connector 5 Ensure that the open circuit voltage of the PV array does not exceed the maximum DC input voltage of the in...

Страница 31: ...e the inverter Make sure all DC connectors are securely sealed Danger to life due to electric shock when live components are touched Disconnect the inverter from all voltage sources before connect the...

Страница 32: ...use RS485 cable maximum length 1000m Procedure 1 Take out the cable fixing accessory from the package 2 Unscrew the swivel nut of the M25 cable gland remove the filler plug from the cable gland and k...

Страница 33: ...twork cable into the RS485 communication client attached 5 Insert the network cable into the corresponding communication terminal of the inverter according to the arrow sequence tighten the thread sle...

Страница 34: ...5 0 6 Nm 2 Remove the dust cap from the terminal of the meter connector and connect the meter plug 5 6 3 WiFi 4G stick connection 1 Take out the WiFi 4G modular included in the scope of delivery 2 At...

Страница 35: ...rnal WiFi 4G stick module The connection diagram between the inverter and internet is shown as following two pictures both two methods are available Please note that each WiFi 4G stick can only connec...

Страница 36: ...loud Web or AISWEI APP 6 2 Active power control with Smart meter The inverter can control activepower output via connecting smart meter following picture is the system connection mode through WiFi sti...

Страница 37: ...RM 1 Do not consume power DRM 2 Do not consume at more than 50 of rated power DRM 3 Do not consume at more than 75 of rated power AND Source reactive power if capable DRM 4 Increase power consumption...

Страница 38: ...w solplanet net for more information and download the user manual for the AiCom 6 4 Communication with third party devices Solplanet inverters can also connect with one third party device instead of R...

Страница 39: ...make sure the DC voltage has the correct polarity Check the PV array s insulation to ground with a multimeter make sure that the insulation resistance to ground is greater than 1 MOhm Risk of injury...

Страница 40: ...After finishing the electrical and mechanical checks switch on the DC switch Choose suitable safety code according to the location of installation please visit website https solplanet net installer ar...

Страница 41: ...or sufficient DC input voltage and cannot feed power into the grid Checking When the initial voltage of the strings exceeds the start up DC input voltage the inverter will check feeding conditions at...

Страница 42: ...522 41 8 Operation The information provided here covers the LED indicators 8 1 Overview of the panel The inverter is equipped with three LEDs indicators Object Description A Normal White LED B Communi...

Страница 43: ...he LED A pulses fast or slow If the power is less than 45 of power the LED A pulses slow If the power is greater than 45 of power and less than 90 of power the LED A pulses fast The LED A is glowing w...

Страница 44: ...meter to ensure that no current is present in the DC cables 4 Release and remove all DC connectors Insert a flat blade screwdriver or an angled screwdriver blade width 3 5 mm into one of the slide slo...

Страница 45: ...x PV array power STC 7500Wp 9000Wp 12000Wp 15000Wp Max input voltage 600V MPP voltage range 80V 550V Rated input voltage 360V Initial feeding in voltage 100V Min feed in power 20W Max input current pe...

Страница 46: ...0V 230V 180V 295V AC power frequency range 50 60 5Hz Rated power frequency rated grid voltage 50Hz 220V 230V Max output current 25A 30A 40A 50A Max output fault current 50 3A 50 3A 62 9A 62 9A Max out...

Страница 47: ...V 295V AC power frequency range 50 60 5Hz Rated power frequency rated grid voltage 50Hz 220V 230V Max output current 21 7A 30A 40A 45 5A Max output fault current 50 3A 50 3A 62 9A 62 9A Max output ove...

Страница 48: ...ncept convection Noise emission typical 39 dB A 1m Installation indoor outdoor Mounting information wall mounting bracket DC connection technology XLIX AC connection technology Plug in Connector Opera...

Страница 49: ...lity Residual current monitoring GFCI function Earth Fault Alarm cloud based audible and visible AU Protection class according to IEC 62103 overvoltage category according to IEC 60664 1 I II DC III AC...

Страница 50: ...de 0 4 2 5 Smart meter connector Stick Hand tight Socket wrenc h Open end of 33 Swivel nut of M25 cable gland Hand tight Open end of 15 Swivel nut of sunclix connector 2 0Nm Wire stripper Peel cable j...

Страница 51: ...urs it might be that the internal circuit has broken Contact the service 33 Check the grid frequency and observe how often major fluctuations occur If this fault is caused by frequent fluctuations try...

Страница 52: ...nd the fault still occurs please call service 38 Check the PV array s insulation to ground and make sure that the insulation resistance to ground is greater than 1 MOhm Otherwise make a visual inspect...

Страница 53: ...the inverter and the cables for visible damage Disconnect the inverter from all power sources before cleaning Clean the enclosure with a soft cloth Ensure the heat sink at the rear of the inverter is...

Страница 54: ...y within the scope of the EU directives Electromagnetic compatibility 2014 30 EU L 96 79 106 March 29 2014 EMC Low Voltage Directive 2014 35 EU L 96 357 374 March 29 2014 LVD Radio Equipment Directive...

Страница 55: ...the right to refuse to provide with the relevant warranty service 16 Contact If you have any technical problems concerning our products please contact AISWEI service We require the following informati...

Страница 56: ...d Level 40 140 William Street Melbourne VIC 3000 Australia AISWEI B V Hotline 31 208 004 844 Netherlands 48 134 926 109 Poland Service email service eu aiswei tech com Add Muiderstraat 9 G Amsterdam 1...

Страница 57: ......

Отзывы: