UM0012_ASW 5-10k Series_EN_V03_0522 37
The RJ45 socket pin assignments for demand response modes as follows:
Pin1--------DRM 1/5
Pin2------- DRM 2/6
Pin3------- DRM 3/7
Pin4------- DRM 4/8
Pin5------- RefGen
Pin6------- Com/DRM0
Pin7--------N/A
Pin8------- N/A
If DRMs support is required, the inverter should be used in conjunction with
AiCom. The Demand Response Enabling Device (DRED) can be conneted to
the DRED port on AiCom via RS485 cable. You can vist the website
www.solplanet.net
for more information and download the user manual for
the AiCom.
6.4 Communication with third-party devices
Solplanet inverters can also connect with one third party device instead of
RS485 or WiFi stick, the communication protocol is modbus. For more
information, please contact the Service.
6.5 Earth fault alarm
This inverter complies with IEC 62109-2 clause 13.9 for earth fault alarm
monitoring. If an Earth Fault Alarm occurs, the red color LED indicator will light
up. At the same time, the error code 38 will be sent to the AISWEI Cloud.
(This function is only available in Australia and New Zealand)