UM0012_ASW 5-10k Series_EN_V03_0522 11
3.2 Checking for transport damage
Thoroughly inspect the packaging upon delivery. If you detect any damage to
the packaging which indicates the inverter may have been damaged, inform
the responsible shipping company immediately. We will be glad to assist you if
required.
4 Mounting
4.1 Ambient conditions
1. Be sure the inverter is installed out of the reach of children.
2. Mount the inverter in areas where it cannot be touched inadvertently.
3. Ensure good access to the inverter for installation and possible service.
4. Make sure that heat can dissipate, observe the following minimum
clearance to walls, other inverters, or objects:
5. The ambient temperature is recommended below 40°C to ensure optimal
operation.
6. Recommend to mount the inverter under the shaded site of the building or
mount an awning above the inverter.
7. Avoid exposing the inverter to direct sunlight, rain and snow to ensure
optimal operation and extend service life.
Direction
Min. clearance
(
mm
)
above
500
below
500
sides
300