CSW-H85K2 User Manual Ver. 1.2
- 70 -
7.4.2
Factory Reset
It is a function physically initializes all the setting. You can save a setting to user-defined
ENV region and use it as default values by the factory reset. However, if you do not use the
region, Factory Reset uses a factory default by manufacturer as its default values.
⚫
Using Factory Reset
①
Move the function switch to the left(SET).
Figure 7-9 setting of Serial Configuration mode
②
Push the function button over 5 seconds.
③
Factory Reset will be automatically implemented to default values.
④
Move the function switch to the middle(RUN).
⑤
Reboot.
⚫
Setting custom default values
①
Change the mode to Serial Configuration
②
Save custom default values by ezManager or serial configuration commands
③
Input the command below
b
<SPACE>
3c5a
<CR>
④
After step
③
, current values in the SRAM is saved in user-defined ENV region and
the values will be always used for Factory Reset.