CSW-H85K2 User Manual Ver. 1.2
- 37 -
5
Communication Modes
5.1
TCP Server
In this mode, CSW-H85K2 listens to a TCP connection request from remote hosts. Once a
host tries connecting to CSW-H85K2, it accepts a connection. After the connection is
established, CSW-H85K2 converts the raw data from the serial port to TCP/IP data and
sends it to the network and vice versa.
5.1.1
Key parameters
⚫
Local Port
This is a server
’
s port number which is used in the TCP connection.
⚫
Event Byte
With setting event bytes, you can handle the serial data of the serial buffer before a
TCP connection is established.
Value
Description
0
CSW-H85K2 does not send the data
Otherwise
(512 or under)
CSW-H85K2 sends the data right after a connection is
established.
512 or under bytes are strongly recommended.
Table 5-1 Event Byte
⚫
Timeout
If there is no transmission data for amount of the time the connection would be
terminated.
⚫
Notify IP Change
This function is for notifying information about changed IP addresses to a
management server. Not only can the TCP/UDP protocol be used, but Dynamic
Domain Name Service (DDNS).
⚫
Access restriction
You can block TCP connections from unauthorized hosts by using this option. Both IP