CSW-H85K2 User Manual Ver. 1.2
- 49 -
5.4
UDP
UDP has no connection processes. In this mode, data is sent in block units. Therefore,
data that comes through CSW-H85K2
’s serial port
is collected in block units to send it
elsewhere.
5.4.1
Key parameters
⚫
Block Size
[Block Size] is to set the time to gather data in one block. Its unit is byte. If the data
in configured size of the [Block Size] comes into the serial port, CSW-H85K2 will send
them as one block to the network. The maximum value could be 1460 bytes.
⚫
Data Frame
[Data Frame] means the time for gathering data to make one block. Its unit is 10ms.
If there is no data from the serial devices during the [Data Frame] time, CSW-H85K2
sends and receives data in the buffer as one block to the network.
Once one of the two parameters, [Block Size] and [Data Frame], is sufficient, UDP
packet block will be transmitted.
⚫
Dynamic update of Peer host
If you set the value of [Peer Address] and [Peer Port] to 0, [dynamic update of peer
host] function is activated. By using this function, CSW-H85K2 can communicate to
multiple hosts without additional setting.