CSE-M32 Users
’
Manual Ver. 2.2
Sollae Systems Co., Ltd.
- 10 -
http://www.sollae.co.kr
18
GND
Ground
-
M
19 UART_RXD1
UART1 (COM2) Receiving Port
In
O
20 UART_RXD0
UART0 (COM1) Receiving Port
In
O
21 UART_CTS1
UART1 (COM2) CTS
In
O
22 UART_CTS0
UART0 (COM1) CTS
In
O
23
DRXD
Port for factory
In
X
24
GND
Ground
-
M
2.3.4
DC Electric Characteristics
The followings are the DC electric Characteristics of the each pin.
Symbol
Min
Max
Unit
V
IL
-0.3
0.8
V
V
IH
2.0
5.5
V
V
OL
0.4
V
V
OH
VCC_33 – 0.4
V
2.4
Serial Interface
There are two serial ports in CSE-M32. Each port can be configured independently.
2.4.1
Serial Type
User can set RS232, RS422 and RS485 to CSE-M32‟s serial port. If CSE-M32 is configured
as RS485, the RTS pin operates as TXDE for RS485 line driver. (The TXDE is Low when CSE-
M32 doesn‟t send data to its serial port and High when CSE-M32 sends data to its serial
port.)
2.4.2
Serial Baud rate
The following is configurable Baud rate table.
COM1
COM2
Etc.
300
300
600
600
1200
1200
2400
2400
4800
4800
9600
9600