CSE-M32 Users
’
Manual Ver. 2.2
Sollae Systems Co., Ltd.
- 11 -
http://www.sollae.co.kr
14400
14400
19200
19200
38400
38400
57600
57600
115200
115200
230400
230400
460800
460800
921600
921600
1843200
-
If COM1 is set as 1843200, COM2 is disabled.
The maximum Baud rate of COM1 is 1,843,200bsp, and the maximum Baud rate of COM2
is 921,600bps. If COM1 is set as 1,843,200bps (its maximum Baud rate), the COM2 port is
disabled. (unavailable)
2.4.3
Data bits, Parity, and Stop bit
Item
Configurable Value
Data bit
8, 7, 6, 5
Parity
None, Even, Odd, Mark, Space
Stop bit
1, 1.5, 2
2.4.4
Flow Control
CSE-M32 support RTS/CTS Hardware Flow Control. RTS pin is for notifying connected
serial devices that its buffer can be available to receive data. CTS pin is for checking that
the RTS signal of its counterpart. To use this control CSE-M32 should be set to the type of
serial communication is RS232.
2.4.5
Telnet COM Port Control Option (RFC2217)
CSE-M32 has Telnet COM Port Control Option function that is specified by RFC2217. If
the Telnet COM Port Control Option is enabled, CSE-M32 sends the CTS control signal to
the communication counterpart, and CSE-M32 sets its serial port items (RTS, baud rate,
data bits, parity, stop bit) after getting information from the communication counterpart.
2.4.6
Disable TCP Transmission Delay
If you use this option, CSE-M32 sends the data from the serial port to Ethernet as quickly
as possible.
2.4.7
FIFO
Activating this option, CSE-M32 read the serial data with 100ms intervals. If you disable
this option, CSE-M32 read the data in every single byte but it might cause data loss with