background image

CSE-M32 Users

  Manual Ver. 2.2

 

Sollae Systems Co., Ltd.   

- 23 - 

http://www.sollae.co.kr

 
 

 

 

Содержание CSE-M32

Страница 1: ...Sollae Systems Co Ltd http www sollae co kr Serial Device Server CSE M32 Users Manual Version 2 2 2011 08 03...

Страница 2: ...or the package indicates that disposal of this unit after its lifecycle could harm the environment Do not dispose of the unit as unsorted municipal waste it should be brought to a specialized company...

Страница 3: ...Data bits Parity and Stop bit 11 2 4 4 Flow Control 11 2 4 5 Telnet COM Port Control Option RFC2217 11 2 4 6 Disable TCP Transmission Delay 11 2 4 7 FIFO 11 2 4 8 Data Frame Interval 12 2 4 9 TX inte...

Страница 4: ...4 5 1 Operation Mode Overview 24 5 1 1 Overview 24 5 2 How to Initiate Each Operation Mode 24 5 2 1 Normal Mode 24 5 2 2 How to Initiate the Serial Configuration Mode 24 5 2 3 How to Initiate the ISP...

Страница 5: ...f Active Connection with host name 36 7 6 3 Example of passive Connection 37 7 7 Example of TCP Disconnection 37 7 7 1 Example of active disconnection 37 7 7 2 Example of passive disconnection 37 8 SE...

Страница 6: ...JP10 47 10 3 3 Reset Switch S1 47 10 4System LEDs classified each mode 48 10 5Schematic of the evaluation board 49 11 TECHNICAL SUPPORT WARRANTY AND NOTES ON OPERATION 51 11 1Technical Support 51 11 2...

Страница 7: ...se TCP IP communication the Internet communication function simply by connecting the cable to a serial port ezTCP sends data from the serial port to the Internet network after TCP IP processing and vi...

Страница 8: ...d when COM1 is 1843200bps RTS CTS flow control Network Ethernet 10 100 M bit auto sense Auto MDI MDIX Protocols TCP UDP IP ICMP ARP DHCP PPPoE Telnet DNS Lookup DDNS Telnet COM Port Control Option RFC...

Страница 9: ...d M 2 TP_IN Ethernet In In M 3 TP_IN Ethernet In In M 4 PWFBOUT PWFBOUT In M 5 TP_OUT Ethernet Out Out M 6 TP_OUT Ethernet Out Out M 7 GND Ground M 8 LAN_RXD LAN RXD LED Blink There are data on Ethern...

Страница 10: ...SPI MOSI Master Out Slave In In N A 8 CN1 TCP Connection 1 Status Low UART1 s TCP connection is established Out O 9 SPI_SCK SPI SCK SPI Serial clock In N A 10 ISP ISP If this pin is low when it boots...

Страница 11: ...ymbol Min Max Unit VIL 0 3 0 8 V VIH 2 0 5 5 V VOL 0 4 V VOH VCC_33 0 4 V 2 4 Serial Interface There are two serial ports in CSE M32 Each port can be configured independently 2 4 1 Serial Type User ca...

Страница 12: ...lable to receive data CTS pin is for checking that the RTS signal of its counterpart To use this control CSE M32 should be set to the type of serial communication is RS232 2 4 5 Telnet COM Port Contro...

Страница 13: ...ng 1 byte For example if you set this value to 5 each byte will be transferred with duration of sending 5 bytes 2 4 10 TCP Server Client mode This mode is available on TCP client mode only In this mod...

Страница 14: ...CSE M32 Users Manual Ver 2 2 Sollae Systems Co Ltd 13 http www sollae co kr...

Страница 15: ...R2 49 9 1 JP2_13 JP1_11 D3 LED 1 2 JP2_5 JP2_18 JP2_24 VCC_33 D2 LED 1 2 S1 SWITCH R3 330 JP2_2 JP2_3 VCC_33 JP1_10 RXD0 2 MISO 2 JP1_2 D6 LED 1 2 JP2_21 JP2_8 DRXD 2 SY S_RST JP1_8 JP1_7 R6 330 JP1_...

Страница 16: ...supply If the LAN cable has been correctly connected when power is supplied LINK LED will be turned on 3 1 3 Configuring CSE M32 Configure CSE M32 setting using ezManager the ezTCP configuration progr...

Страница 17: ...nication Mode T2S TCP Server Local Port 1470 1471 3 1 4 Communication Test Power the CSE M32 off and on then it tries to connect to the LAN A program for testing starts if you press the Simple Test bu...

Страница 18: ...on after selecting serial port that is connected to the CSE M32 If the serial port is open the COM1 the COM port has opened message will be shown If you press the Send Data button on the LAN part Top...

Страница 19: ...http www sollae co kr If you press the Send Data button on the RS232 part Bottom the data shown in the Send box will be transmitted to the Receive box on the LAN part If the transmitting and receivin...

Страница 20: ...on utility which allows you to configure your CSE M32 over the network or by using AT commands in ATC mode 4 2 Configuration with ezManager 4 2 1 ezManager The basic environmental variables IP address...

Страница 21: ...figure a set of values to one or more ezTCP PING ARP Test the PING reply and manage the ARP table Simple Test Run the test program interfaced with Network and RS232 port Windows Firewall Run the windo...

Страница 22: ...ld be used with MAC address If they are connected on Internet Read on the IP tap could be used Using RS232 Port For use ezManager through RS232 not only the CSE M32 should be connected to PC with RS23...

Страница 23: ...s this problem There are 3 types DDNS TCP and UDP for this service 4 6 1 DDNS Dynamic Domain Name System If the CSE M32 obtains its IP address it notices to the service provider Then the service provi...

Страница 24: ...CSE M32 Users Manual Ver 2 2 Sollae Systems Co Ltd 23 http www sollae co kr...

Страница 25: ...nitiate the Serial Configuration Mode Inputting low signal to the ISP pin from 20ms to 1000ms CSE M32 works in the serial configuration mode 5 2 3 How to Initiate the ISP Mode The CSE M32 checks its I...

Страница 26: ...t Topology T2S TCP Passive Connection Not needed Impossible 1 1 ATC TCP Active Passive Connection Needed Possible 1 1 COD TCP Active Connection Not needed Impossible 1 1 U2S UDP No Connection Not need...

Страница 27: ...the security options including ezTCP firewall are removal The following is the firmware downloading procedure Supply power with ISP pin low then CSE M32 operates in the ISP mode Run hotflash that is...

Страница 28: ...ezTCP Listen on local port Request TCP connection Accept TCP connection ack DATA ABC DATA ABC TCP IP DATA DEF TCP IP DATA DEF connected T2S Mode 6 1 1 TCP Connection If a host connects to the pre def...

Страница 29: ...designated Data Frame CSE M32 will send the saved data If the Data Frame is 0 CSE M32 will send serial port s data immediately The unit used for the Data Frame is 10m seconds so CSE M32 rounds down r...

Страница 30: ...ata before TCP connection will be handled based on the Event Byte settings If the Event Byte is 0 the data that comes to CSE M32 s serial port will not be recognized If it is not 0 the serial data bef...

Страница 31: ...ignated Timeout the TCP connection will be automatically terminated The unit used for Timeout is 1 second 6 2 4 DNS If users set the host name instead of the IP address on the Peer Address box CSE M32...

Страница 32: ...ontrolling the modem using AT command In ATC mode only a TCP connection is possible and both the server and the client can be configured In ATC mode the AT command allows the user to set environment v...

Страница 33: ...zed as one block This block will be sent to UDP Timeout is in 10ms Since UDP communication does not involve establishing connection N M communication may be performed using broadcast Therefore it can...

Страница 34: ...ollowed AT Command CR 0x0d The response code to AT command is followed CR 0x0d LF 0x0a Response message CR 0x0d LF 0x0a Response Message When ATV1 initial setting When ATV0 Description OK 0 command OK...

Страница 35: ...sollae co kr After setting this parameter CSE M32 queries the IP address according to the name and set the IP address to the PRIP parameter PRP Remote machine TCP port PWP Write configuration Saving a...

Страница 36: ...ase of 1 3A or subsequent versions of F W users can select whether data is transmitted or not by using AT PSE command 7 4 2 Changing AT Command State to Online State If CSE M32 s state is in AT comman...

Страница 37: ...le of Active Connection with host name Serial Port Description AT PNIP 168 126 63 1 CR Setting the name server s IP address to connect CR LF OK CR LF Command OK AT PRHN www sollae co kr CR Setting the...

Страница 38: ...ample of TCP Disconnection 7 7 1 Example of active disconnection CSE M32 disconnects the connection Serial Port Description Data Communication during TCP connection Data Frame Data Frame Changing onli...

Страница 39: ...rnet The SSL works over TCP 8 1 2 How to set the SSL on CSE M32 To works for SSL you have to set the SSL related parameters as the following steps Set the SSL check box in the ezManager Log in the CSE...

Страница 40: ...protocol that allows secure communications between two devices You can use this function if your device is a serial port for console and you need secure communication 8 2 2 How to set the SSH on CSE...

Страница 41: ...Server mode if you set the SSH function 8 3 ezTCP Firewall CSE M32 has two connection limitation functions Those can be set by the Option tab of the ezManager Allowed MAC Address If user sets the Allo...

Страница 42: ...this option is checked hosts who are not specified above two restrictions can t search and configure CSE M32 with ezManager This is enabled when one of restrictions is set at least All security funct...

Страница 43: ...is set user can log in the CSE M32 User can monitor the status of the serial ports and the network If user inputs telnet CSE M32 IP Address user can log in the CSE M32 with telnet Then the following m...

Страница 44: ...h the sd command The way of using this command is like below sd SPACE of Serial Port SPACE Interval The value of of Serial Port is that COM1 is 1 and COM2 is 2 Interval means duration of capturing and...

Страница 45: ...the current status of the CSE M32 with ezManager If user sets Refresh Every 1 second option the status data will be updated in every second 9 2 2 Closing TCP connection by the ezManager User can term...

Страница 46: ...g Message field in the OPTION tab of the ezManager CSE M32 transmits debugging messages with UDP port 50006 Then user can get the messages with new window if user presses Debugging Message button as f...

Страница 47: ...M32 The input voltage should be 5V The regulator in the evaluation board regulate the 5V to 3 3V and supplies the 3 3V to the CSE M32 CON1 RJ45 10M 100M Ethernet P1 DB9M RS232 interface for COM1 UART0...

Страница 48: ...en the ISP is high It operates as ISP mode when the ISP is low 10 3 2 JP9 JP10 These pins control the outputs of the RS232 line drivers Connection Input value of RS232 driver Description 1 2 short Hig...

Страница 49: ...g with Ethernet LAN_RX Yellow Blinks Receiving data from Ethernet LAN_TX Green Blinks Sending data to Ethernet SIO1 SIO2 RXD0 1 Yellow Blinks Receiving data from Serial ports TXD0 1 Green Blinks Sendi...

Страница 50: ...P2_7 JP1_5 DTXD 2 JP1_1 JP2_1 R8 330 JP1 HEADER 12 1 2 3 4 5 6 7 8 9 10 11 12 JP2_19 VCC_33 JP1_8 JP2_21 JP2_12 CTS1 2 JP1_7 JP2_20 UART SYS_RST INPUT HIGH NORMAL LOW RESET CON1 RD1 126BAG1A 1 2 3 7 8...

Страница 51: ...DER 6 1 2 3 4 5 6 D12 LED 1 2 CONSOLE C10 100nF 1 2 VCC_33 DRXD 1 VCC_EXT EN_COM2 TXD0 D16 LED 1 2 EN_COM1 VCC_5 VCC_33 CTS0 R10 330 HIGH ENABLE RS232 DRIVER LOW DISABLE RS232 DRIVER VCC_33 TXD0 H4 HO...

Страница 52: ...ms provides free repair services or exchange the product However if the product failure is due to user s fault repair service fees will be charged or the product will be replaced at user s expense 11...

Страница 53: ...nvironment in which humidity is high or a lot of oil exists Do not use the product where there is caustic or combustible gas Sollae Systems does not guarantee normal operation of the product under the...

Страница 54: ...5 connectors Jan 08 2009 1 5 Add Security Function in the ISP mode Feb 26 2009 1 6 Add DC Electric Characteristics Mar 04 2009 1 7 Add description of serial I O data capture by using telnet sd command...

Страница 55: ...rade Modify the 4 6 Notify IP change Change the form of document Correct some expressions Dec 02 2009 2 1 The table of JP2 has been modified Form of Revision History has been modified Operating Storag...