Each channel presents the following areas:
1 BUSES:
Each of the 24 channels can be as-
signed to 4 mix buses:
PGM; REC; AUX; VBUS
On the UX24 surface physical channels 1 to 12 are
assigned to PGM, REC and AUX directly from three
assignment buttons present on each channel. When
is assigned, the button lights orange.
The assignment to the VBUS is made from the
touch screen, from CHANNEL screen or from the
WEB interface (see below).
2 CUE/SELECT:
This button have 3 functions:
•
CUE, pre-fader listening (PFL)
•
SELECT, channel selection
•
TALKBACK in channels with mode=TELCO
In
normal use
they work as CUE buttons, to listen to
the signal present on that channel, prior to the atten-
uator and the ON-AIR button.
The
SELECT
fuction is used to select a specific
channel and perform some operation, for example,
set the gain, equalization, edit the label, etc. When
the SELECT is activated the CUE buttons change to
blue and SELECT is indicated on the OLED screen.
The use of this mode is detailed below.
TALK-BACK
mode is exclusive to TELCO channels,
which handle telephone lines. By holding down CUE,
the built-in talk-back microphone is activated to talk
to the telephone line.
3 ON-AIR button:
It’s the ON/OFF button. When
is ON, the signal sends on-air (to the mix
buses). The level is set with the main fader.
4 DISPLAY:
OLED screen that shows:
•
The input level previous to fader. If the input
signal is reaching 0 dBfs at the A/D con-
verter, a
CLIP indication
appears. To solve
this condition, turn down the input gain.
•
Name or label that identify the channel.
•
States or special modes like SELECT or
channel functions like TELCO.
OLED ENERGY SAVER
The
brightness of OLED displays
is reduced after 5 min-
utes of inactivity. After 15 minutes, the OLEDs turn off.
Any action on the channel controls or the Intercom but-
tons restores the displays.
5
MAIN FADER:
100mm soft touch faders.
Sets the level for the signal on outputs assigned to
the buses. The final level of each mix bus shows on
the main screen. PGM meters keeps visible at all
screens
.
5.4 Monitoring section
In this section of the console, the operator assigns
the signals that will be heard on the monitor speak-
ers and headphones of the Studio and Control
Room.
Also located in this sector are the microphone acti-
vation master buttons A and B, the CUE level control,
the talk-back command microphone and the inter-
com groups.
www.SolidynePro.com
Solidyne UNIDEX UX24
Page 29
Содержание UNIDEX UX24
Страница 1: ......
Страница 2: ...Page 2 Solidyne UNIDEX UX24 www SolidynePro com...
Страница 6: ...Page 6 Solidyne UNIDEX UX24 www SolidynePro com...
Страница 44: ...EMPTY PAGE Page 44 Solidyne UNIDEX UX24 www SolidynePro com...
Страница 46: ...EMPTY PAGE Page 46 Solidyne UNIDEX UX24 www SolidynePro com...