nel is assigned to all buses, the mix-minus is done
against PGM. But if the channel is assigned, for ex-
ample to REC and AUX, the mix-minus is done
against REC.
9 – CHANNEL:
It shows the input associated with
the selected output, and the channel assigned to
that input. These fields are not editable. The input
associated with each output for mix-minus is prede-
termined and cannot be modified.
OUT5-L
UDX1-L
OUT5-R
UDX1-R
OUT6-L
UDX2-L
OUT6-R
UDX2-R
OUT7-L
UDX3-L
OUT7-R
UDX3-R
OUT8-L
UDX4-L
OUT8-R
UDX4-R
USB OUT1-L
USB IN1-L
USB OUT1-R
USB IN1-R
USB OUT2-L
USB IN2-L
USB OUT2-R
USB IN2-R
USB OUT3-L
USB IN3-L
USB OUT3-R
USB IN3-R
USB OUT4-L
USB IN4-L
USB OUT4-R
USB IN4-R
In order for an output to be used in MIX-MINUS
mode, the associated input must be assigned to a
channel. If the input is not routed, the MIX-MINUS
mode remains disabled.
4.6 SYS CONFIG
1 CHANNEL ON-AIR ON STARTING
Set one input that will be aired in case the console
restarts due to power failure.
Start on-air input:
Select an input. It can be as-
signed to a channel (hardware or virtual). The con-
sole always starts with the last scene used. If the
station is in automated transmission, verify that
the scene used has the channel set to the input de-
fined for “automatic start”. Logically, the audio
source connected to that input must also be re-es-
tablished by itself.
Default BUS:
Buses that will be turned on at the
channel associated with the “default” input.
Start Level:
Channel’s fader level. In physical chan-
nels, this level is independent of the position of the
mechanical fader, but if the fader is moved, the
level will change to the current position of the
fader.
2 NETWORK SETTINGS
(Ethernet control)
LAN settings for remote control. By default the de-
vice works with DHCP enabled. The IP assigned by
the router is shown on the main screen (UNIDEX IP).
The IP address allows the user access to the con-
sole using a web browser. UX24 has an internal
HTML5 server, which allows remote control over all
the operation features and settings.
3 CLOCK SETTINGS
Shows a pop-up box to set the time. The clock can
be setled in three ways:
1.
Connecting the UX24 to a LAN with Internet us-
ing
Ethernet STREAMING
port. In this case the
sync is full automatic. No other action is re-
quired.
2.
Connecting the UX24 to a LAN with Internet us-
ing
Ethernet CONTROL
port. In this case an in-
ternal clock UX-Core is synchronized.
The user
must sync manually the internal computer
(wich controls the touch screen interface)
by
touching the option SYNC FROM UX-CORE
showed on screen.
3.
Manually from the screen. Used when the LAN
do not have Internet access.
NOTA
When UX24 access to Internet, it synchronizes with
a World Clock (UTC). The user must define the
Time Zone
according to correspond.
Page 24
Solidyne UNIDEX UX24
Содержание UNIDEX UX24
Страница 1: ......
Страница 2: ...Page 2 Solidyne UNIDEX UX24 www SolidynePro com...
Страница 6: ...Page 6 Solidyne UNIDEX UX24 www SolidynePro com...
Страница 44: ...EMPTY PAGE Page 44 Solidyne UNIDEX UX24 www SolidynePro com...
Страница 46: ...EMPTY PAGE Page 46 Solidyne UNIDEX UX24 www SolidynePro com...