
Appendix G - Service
167
Matrix
2
Owner’s Manual
VU Meter calibration
• Route a calibrated 0 VU source to the left Mix insert return. Alternatively, connect a level meter to the console’s Mix
bus output, route a tone to the Mix bus and set the master fader to give a reading of 0 VU on the output.
•
Deselect the Mix insert sum function.
•
Deselect the VU meter -10dB function.
®
& ` ` #
pot to align the left VU meter needle with the 0 VU legend.
•
Repeat for the procedure for the right meter.
Содержание Matrix2 Delta
Страница 37: ... Chapter 2 Getting Started 29 Matrix2 Owner s Manual ...
Страница 128: ... Chapter 6 DAW and CC Configuration 120 Matrix2 Owner s Manual ...
Страница 136: ...Appendix B Technical Specifications 128 Matrix2 Owner s Manual ...
Страница 140: ... Appendix D Environmental Specifications 132 Matrix2 Owner s Manual ...
Страница 142: ... Appendix E Software Updates 134 Matrix2 Owner s Manual ...
Страница 178: ... Appendix G Service 170 Matrix2 Owner s Manual ...
Страница 179: ......