30
4.8.3
Wiring box conduit openings
Figure 26: Wiring box conduit opening locations
Conduit openings are provided for 1 inch and ½ inch conduit fittings. If conduit fitting used is bet
-
ween 1 inch and ½ inch (2.54 cm and 1.27 cm), an appropriate conduit reducer should be used.
Do not enlarge the wiring compartment conduit openings as the
wiring box enclosure will be damaged which will void the inverter
warranty.
CAUTION!
PRUDENCE!
1 in. 1 in.
1 in.
1 in.
1/2 in.
Figure 27: Wiring box conduit plug removal (illustration showing
the removal of a conduit plug)
The conduit plugs are removed by pla-
cing a flat blade screwdriver in the slot
on the conduit plug face and turning
while gripping the nut on the inside
of the enclosure to ensure it does not
slip. Unscrew the nut from the conduit
plug and slip the conduit plug out of
the conduit opening.
1 in.
1 in.
Содержание PVI 3800TL
Страница 1: ...PVI 3800TL PVI 5200TL PVI 6600TL PVI 7600TL Installation and Operation manual for ...
Страница 92: ...91 ...