Configuring the Ports
71
• ADP mode - applies only if Automatic Discovery Protocol is enabled.
Auto
Acceptance
is the default. If you set ADP mode to
Manual Acceptance
, you
must configure the base station to manually accept the sub stations.
• ADP Timeout Interval - applies only if Automatic Discovery Protocol is
enabled.
When finished setting the base port configuration, type
.W
to update the database.
6.
Initialize the RF port. At this point, you have made the changes to the database, but
before the changes take affect, you must initialize the port. There are two ways to
do this:
• Cycle the port:
a. Go to 2.2.1 Generic Port Status and Control.
b. Type 3 (or
.N
until the port number is 3).
c. Set the Administrative Status field to
Cycle.
d. Type
.W
Cycle
evacuates the port, eliminates the driver, reads the database, reinstalls the driver,
and brings up the port.
• Reset the unit:
a. Go to the Main Menu
b. Type 5 (Start Application).
c. Choose
Run Time
as the Application to Start.
This reloads the updated database containing the new configuration parame-
ters.
You can configure only one base station, but you can configure as many as 64 sub
stations.
Содержание skyway series
Страница 12: ...x ...
Страница 26: ...xxiv Index 229 ...
Страница 52: ...26 ...
Страница 66: ...40 ...
Страница 82: ...56 ...
Страница 150: ...124 ...
Страница 174: ...RF DLC Screens 148 Rcv Timeouts Sec swSignalStatusRcvToR ate The rate of receiver timeouts Field Name MIB Comments ...
Страница 196: ...Status Summary 170 ...
Страница 214: ...188 ...
Страница 218: ...192 ...
Страница 222: ...196 ...
Страница 238: ...212 ...
Страница 254: ...228 ...