70
2.
Configure the RF Transceiver settings: RF Frequency, RF Data Rate, and Scrambler
Tap Values.
a. Go to screen 1.2.3.3 RF Transceiver Configuration, described in detail on
b. Set the RF Frequency, RF Data Rate, and Scrambler Tap values.
c. Press
.W
to update the database.
3.
Invalidate the RF Diagnostics Port configuration. As shipped, the default RF port is
the RF-DLC Sub Diagnostics Port. You must invalidate it before setting the RF port
up as a base port.
a. Go to 1.2.3.2 RF Diagnostic Port Configuration, described in detail on
page 73. The port number is
3
, and the port type is
Sub Diag
, which is the
default.
b. Set the Record Type field to
Invalid.
c. Press
.W
to remove this configuration record from the database.
4.
Configure the RF port as a base port.
a. Go to 1.2.3.1.1 RF Base Port Configuration, described in detail on
b. Press
.A
. This automatically adds port 3 as a base port. The fields now
contain the default settings.
5.
Accept the defaults or change the base port configuration settings:
• Configuration Status - You might want to set this
Off-line
to complete configur-
ing all your units, then change the configuration status of all units to
On-line
before rebooting (see step 5).
• Max Buffers - these are the message buffers for the system.
• Transmit and Receive Buffers - these are shared between the serial and RF
ports. There are 512 total.
• Maximum Frame Size - The physical MTU (not configurable).
• Slow Polling Timeout - number of seconds that elapse before the base station
checks the sub stations on the slow poll list.
• First Sub Station Number - logical address of the first sub station (default is
256).
• Last Sub Station Number - logical address of the last sub station in the topol-
ogy.
• Automatic Discovery Protocol - if enabled, the base station uses ADP to send
broadcasts to the sub stations. You must also configure the ADP mode. If dis-
abled, ADP mode does not apply, there fore you must manually configure the
base station for the base sub ports (see “Configuring the Base Sub Ports” on
Содержание skyway series
Страница 12: ...x ...
Страница 26: ...xxiv Index 229 ...
Страница 52: ...26 ...
Страница 66: ...40 ...
Страница 82: ...56 ...
Страница 150: ...124 ...
Страница 174: ...RF DLC Screens 148 Rcv Timeouts Sec swSignalStatusRcvToR ate The rate of receiver timeouts Field Name MIB Comments ...
Страница 196: ...Status Summary 170 ...
Страница 214: ...188 ...
Страница 218: ...192 ...
Страница 222: ...196 ...
Страница 238: ...212 ...
Страница 254: ...228 ...