Sensor Data
Coolant temperature sensor
Measuring range: -40ºc to 130ºC
Shutdown: 93ºC
Coolant pressure sensor
Measuring range: 0 to 6 bar
Shutdown: 0,5 Bar
Coolant temperature switch
Measuring range: -40ºC to 250ºC
Shutdown: 95ºC
Differential range: 6ºC
Oil pressure sensor
Measuring range: 0 to 10 bar
Shutdown: 1,6 bar
Oil temperature sensor
Measuring range: -50ºC to 200ºC
Shutdown: 95ºC
Oil pressure switch
Measuring range: 0,5 to 3 bar
Shutdown: 1,4 bar (delay < 4 ms)
Differential range: 0,25 to 0,80 bar
Exhaust temperature sensor*
Measuring range: -50ºC to 800ªC
Shutdown: 550ºC
*Optional equipment.