Systems and scheduled
maintenance
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · [email protected]
36
Marine Diesel gensets. Operator’s Manual.
4.
Clean the threaded hole of the heat exchanger and coat the threads of anticorrosion zinc
anode. Install the anticorrosion zinc anode into the heat exchanger.
5.
Close the coolant drain plug and open the seacock. Refill the coolant circuit.
6.
Start the genset and check for leaks at the anticorrosion zinc anode location. The pump is
operating if the seawater flows from the exhaust outlet.
5.7.
Inlet and Exhaust System
Exhaust circuit description
There are two possible installations of the exhaust system. You need to check the distance
between water injection point and waterline to decide which type of installation you need. This
information is specified in the following drawings.
The elements included in the drawing are essential for the correct genset operation:
-
Waterlock (supplied as accessory) to prevent seawater from entering inside the engine when
it stops.
To calculate the required collector capacity, we must follow the following formula:
-
Goose neck (supplied as accessory)
-
Siphon breaker (supplied as accessory)
–
needed in case there is less than 150 mm between
the water injection point of wet exhaust and the waterline, or if the point of injection is below
waterline.
Type 1 installation. When between water injection point of wet exhaust and waterline is minimum 150
mm.
C = collector capacity (L)
D = Inside diameter of the tube (mm)
L = Tube length (mm)
𝐶
=
𝜋
4
𝐷
2
∗ 𝐿
1000000
∗
0.5
M
A
X
.
1
5
0
0
m
m
M
IN
.
4
5
0
m
m
M
IN
.
5
0
m
m
M
IN
.
1
5
0
m
m
W.L.
L
=
M
IN
. 3
00
m
m
L = MAX. 3000 mm