8
INSTALLATION REQUIREMENTS
Hearth Requirements
The heater and face must not contact any combustible surfaces. A minimum 1” clearance to a combustible
floor is required. A non-combustible hearth extension is not required. However, if the heater is installed
close to the floor, we recommend a hearth to protect the flooring surface from discoloration or other negative
impact from the heater.
The gas fireplace insert is shipped with a 3/8” stainless steel flex connector. The gas supply piping should
have a separate gas shutoff valve and a 1/8” NPT plugged tapping upstream of the valve. The stove and its
main control valve must be disconnected from the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1/2 psi (3.5 kPa). The fireplace insert must be isolated from the gas
supply piping system by closing the main control valve during any pressure testing of the gas supply system
at test pressures equal to or less than 1/2 psi (3.5 kPa). After the gas supply has been connected, use a com-
mercial gas leak detector or apply a soapy water solution to all the fittings to check for gas leaks. Never use
a flame to test for leaks.
REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS
This product must be installed by a licensed plumber or gas fitter when installed within the Common-
wealth of Massachusetts. If this appliance is installed in a dwelling, building or structure used in
whole or in part for residential purposes, a hard-wired carbon monoxide detector with an alarm and
battery back-up must be installed on the floor level of the dwelling, building or structure where the
appliance is to be installed.
Additionally, a hard-wired or battery operated carbon monoxide detector with an alarm must be in-
stalled on each additional level of the dwelling, building or structure served by the appliance. It shall
be the responsibility of the property owner to secure the services of qualified licensed professionals
for the installation of hard-wired carbon monoxide detectors.
In the event that this requirement cannot be met at the time of completion of the installation of the
appliance, the owner shall have a period of thirty (30) days to comply with the requirement. However,
during said thirty (30) day period, a battery operated carbon monoxide detector with alarm must be
installed.
Each carbon monoxide detector as required in accordance with the above provisions must comply
with NFPA 720 and be ANSI/UL 2034 and IAS certified.
In addition when the vent termination is less than seven (7) feet above finished grade a metal or plas-
tic identification plate must be permanently mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the exhaust vent terminal. The sign shall
read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP
CLEAR OF ALL OBSTRUCTIONS”.
Fireplace Dampers must be removed or welded in the open position prior to the installation of a fire-
place insert or Gas Log.
A COPY OF THESE INSTRUCTIONS PLUS ALL VENTING INSTRUCTIONS WHICH IN-
CLUDE PARTS LISTS, AND/OR ALL VENTING DESIGN INSTRUCTIONS MUST REMAIN
WITH THE FIREPLACE AT THE COMPLETION OF THE INSTALLATION.
ATTENTION INSTALLERS: Approved with
Duraflex AL - Flexible Aluminium Pipe
venting system.