background image

24 

 

LIGHTING AND OPERATION 

Содержание FIN-36N

Страница 1: ...he fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Do not store or use gasoline or other flamma ble vapors and liquids in the vic...

Страница 2: ...reil peut tre install dans une maison pr fabriqu e mobile d j install e demeure si kes r glements locaux le permettent Cet appareil doit tre uniquement avec las type de gaz indiqu sur la plaque signal...

Страница 3: ...ATION RECORD FORM 32 WARRANTY INFORMATION 33 TABLE OF CONTENTS WE STRONGLY SUGGEST THAT YOU READ THIS MANUAL THOROUGHLY BEFORE BE GININNG THE INSTALLATION OF THE SOLAS DIRECT VENT GAS FIREPLACE INSERT...

Страница 4: ...w of combustion and ventilation air must not be obstructed Adequate accessibility clearances must be maintained for servicing and proper operation of this appliance Do not use this appliance if any pa...

Страница 5: ...turned off if the appliance will not be in use for an extended period of time This appliance is equipped for use with the fuel type indicated on the rating plate This appliance has been certified by...

Страница 6: ...and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due t...

Страница 7: ...nstalled if the insert is ever removed removal of rivets or screws is acceptable The damper A and grate with log set B must be removed see the illustration below The smoke shelf C internal baffles D s...

Страница 8: ...installed on the floor level of the dwelling building or structure where the appliance is to be installed Additionally a hard wired or battery operated carbon monoxide detector with an alarm must be i...

Страница 9: ...h batteries 5 Fireplace Altered Tag 6 Vent Restrictors x 2 Set these items to one side for use later in the installation process Remove the packaging materials from around the unit and unbolt the unit...

Страница 10: ...1 88 2009 installation code Please consult the installation instructions supplied by the venting manufacturer you are using Additional brand specific installation requirements may apply follow the ins...

Страница 11: ...re beginning the installation and follow the manu facturer s instructions exactly The Following Vertical Termination Caps are the only ones approved for use on this appli ance Simpson Duravent 46DVA V...

Страница 12: ...nt runs may experience over drafting and require the addition of a Vent Re strictor E or F The best indication of over drafting is a hyper active flame pattern flames that move too quickly Over drafti...

Страница 13: ...mine that a restrictor is required in your installation place either the E or F restrictor into the exhaust port of the fireplace insert body PRIOR to reconnecting the Vent Connector Plate to the inse...

Страница 14: ...or less than 1 2 psi 3 5kPa After the gas supply has been connected use a commercial gas leak detector or apply a soapy water solution to all the fittings to check for gas leaks Never use a flame to...

Страница 15: ...the plate with its locating track on the top of the insert body Take care not to damage the sealing gasket affixed to the insert body Pull the locking bar forward to fully engage the vent connector p...

Страница 16: ...so Once all four retaining clips have been released the glass frame can be tipped forward and lifted out of the bottom retaining rail The glass is retained in the frame with retaining tabs so remove t...

Страница 17: ...r When the burner glass media is properly placed it should look like the adjacent illus trations 6 Note If a few pieces of glass escape over the edges of the burner tray during installation it is not...

Страница 18: ...to be in position be fore the Fireplace surround can be installed Installing Front Face Surround Locate the On Off switch connecting cable on the back side of the Front Face Locate the connection poin...

Страница 19: ...e appliance and to replace any part of the control system which has been under water LIGHTING FOR THE FIRST TIME INITIAL LIGHTING Purge air from the supply line as follows Open Main shutoff valve Unsc...

Страница 20: ...evenly distributed across the full width of the burner OPERATING INSTRUCTIONS STOP Read the safety information on the previous page 1 Turn off all electrical power to the appliance Press the on off s...

Страница 21: ...21 LIGHTING AND OPERATION NOTE Not all features available on the SIT Proflame 2 Remote are relevant to the Solas Fireplace Insert Only the features relevant to this product are dis cussed below...

Страница 22: ...22 LIGHTING AND OPERATION...

Страница 23: ...23 LIGHTING AND OPERATION...

Страница 24: ...24 LIGHTING AND OPERATION...

Страница 25: ...25 LIGHTING AND OPERATION...

Страница 26: ...26 LIGHTING AND OPERATION...

Страница 27: ...portant to support both the glass and the frame when handling Place your thumbs on the outside of the glass frame and wrap your fingers around the frame and onto the glass Squeeze the frame and glass...

Страница 28: ...e appointment the service person should clean the burner and firebox To gain access to the firebox and burner follow the instructions beginning on page 16 of this man ual DO NOT USE A VACUUM CLEANER T...

Страница 29: ...nnections Other __________________________ MAINTENANCE LOG Date of Service ____________________ Serviced By ______________________ Service Performed Inspect Venting Clean Burner Firebox Clean Control...

Страница 30: ...PARTS LIST For replacement parts and customer service contact your Solas Fireplace dealer or Hearth Innovations Inc 4 Technology Drive Suite 5 West Lebanon NH 03784 Telephone 603 298 5169 Sales hearth...

Страница 31: ...31 CONTROL SCHEMATIC Caution Label all wires prior to disconnection when servicing the controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing...

Страница 32: ...ow that describes the details of the installation Having this writ ten record of installation information available will greatly expedite trouble shooting should any problem arise with your stove The...

Страница 33: ...33 Warranty...

Страница 34: ...34 V2 8 15 2013 Manufactured by Progressive Manufacturing Inc 4 Technology Drive Suite 5 West Lebanon NH 03784 USA www hearthinnovations com...

Отзывы: