6
INSTALLATION REQUIREMENTS
FIREPLACE REQUIREMENTS
• Insert must be placed within a code-conforming masonry fireplace or tested and listed factory-built
(metal) wood-burning fireplace. Repair any fireplace damage prior to installation.
• Because the insert uses a circulation blower, clean the fireplace, smoke shelf, and chimney prior to
installation.
• This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.
• Installation and repair should be done by a qualified service person. The appliance should be inspected
before use and at least annually by a professional service person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment,
burners and circulating air passageways of the appliance be kept clean.
Minimum Opening
Width. 29.75”
-
additional space may be
required for gas line instal-
lation.
Surround Size Options:
Standard:
26”H x 38”W
Medium:
29”H x 40”W
Large:
32”H x 44”W
The Solas Fireplace Insert
inserts 14.75" deep into the
Fireplace cavity.
For tight fits (under 24") see the section
"Removing the “Vent Connector" See Page
12.