Requirements for the installation location
•
MyReserve must only be installed in dry indoor rooms
or outdoor areas that are protected from spray water.
X
•
Max. relative air humidity: 85%. Do not expose My-
Reserve to environments with higher humidity levels.
•
Optimal ambient temperature range: 0°C to 30°C;
max. permitted ambient temperature: 45°C.
•
Keep the product out of direct sunlight.
•
For the 4.4 kWh design, the wall and the mounting
material must have a static load-bearing capacity of
at least 80 kg.
•
MyReserve must not block access to disconnection
mechanisms at the setup location.
•
For maximum safety, install DC-side lightning and
overvoltage protection between MyReserve and the
PV plant.
•
Keep the product out of reach of children, mentally
handicapped persons, and animals.
•
Install the product in a location where it will not be at
risk of exposure to fl ooding. This is to be ensured by
installing the product at a suffi cient height (at least
20 cm), and in a location protected against water in-
or outfl ow.
•
Do not store fl ammable or explosive materials in the
installation room.
•
Do not install the product in heating rooms (defi ned
as solid-fuel heating systems with total nominal heat
output of over 50kW that cannot be used in other ca-
pacities), oil or wood storage depots, barns, sheds, etc.
NOTE
MyReserve does not operate at temperatures below -15°C or above +45°C. Unrestricted performance is pro-
vided for the household in the temperature range of 0°C to 30°C. Accelerated aging of the cells should be
taken into account at temperatures above +45°C.
NOTE
NOTE
NOTE
NOTE
Make sure that the wall which the MyReserve is to be installed on can support its weight (80 kg) and ensure