![SOLARFOCUS pellettop 35/45 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/solarfocus/pellettop-35-45/pellettop-35-45_operation-manual_1313813009.webp)
4 Product information
Operation manual
pellettop
9
4.11 Technical specifications
pellet
top
35
45
49
70
Rated power
[kW]
35
44.9
49
70
Lowest output
[kW]
10.5
13.4
14.7
21
Energy efficiency class
A+
A+
A+
A+
Dimensions
Width (W)
[cm]
55.5
55.5
79
79
Total width including ash box (B1)
[cm]
94
94
120
120
Total depth
[cm]
144
144
155
155
Depth without fan (D)
[cm]
134
134
145
145
Height incl. adjustable feet
[1]
(H)
[cm]
156
156
172
172
Minimum room height
[2]
[cm]
175
175
195
195
Weight
Weight
[kg]
554
560
882
882
Water side
Water content
[l]
58
58
130
130
Max. permissible operating pressure
[bar]
3
3
3
3
Connection Boiler inflow/Boiler return flow
["]
AG 5/4”
AG 5/4”
AG 6/4”
AG 6/4”
Drain
["]
AG 1/2”
AG 1/2”
AG 1/2”
AG 1/2”
Thermal overload protection
["]
AG 1/2”
AG 1/2”
AG 1/2”
AG 1/2”
Flow rate / differential pressure at ΔT 10°K
[kg/h]
[hPA]
3000
45
3860
95
4200
50.6
6000
59
Flow rate / differential pressure at ΔT 20°K
[kg/h]
[hPA]
1500
11
1930
17.5
2100
13
3000
16
Fuel
Fuel
Wood pellets acc. to EN17225-2, ENplus-A1
Capacity of intermediate pellet store
[l]
95
95
250
250
Flue gas side
Flue gas pipe diameter
[cm]
15
15
20
20
Height centre of flue gas pipe
[1]
(D)
[cm]
46
46
59
59
Flue gas mass flow full load
[g/s]
30
37
40
55
Flue gas mass flow partial load
[g/s]
10
13.5
14
20
Maximum flue gas temperature
[4]
full load
[°C]
140
140
140
140
Maximum flue gas temperature
[4]
partial load
[°C]
100
100
100
100
Minimum draught requirement
[5]
[Pa]
5
5
5
5
Emissions according to test report
Flue gas values
[6]
from test report: Test institute /
test report no.
TÜV Austria11-
UW-Wels-EX-212-
2
TÜV Austria11-
UWWels-EX-619
TÜV Austria11-
UWWels-EX-212
TÜV Austria11-
UW-Wels-EX-212-
1
CO full load
[mg/m³]
10
9.1
8.8
7
CO Partial load
[mg/m³]
48
42.6
40.4
29
NOx full load
[mg/m³]
101
103
104
108
NOx partial load
[mg/m³]
102
106.9
109
119
Org. C full load
[mg/m³]
<2
<2
<2
<2
Org. C partial load
[mg/m³]
<2
<2
<2
<2
Dust content full load
[mg/m³]
20
20
20
20
Dust content partial load
[mg/m³]
17
17.6
17.8
19
[1] Adjustable feet at maximum depth of thread