6 Heating circuit
6 Heating circuit
Fig. 2-24
1 Outside temperature
2 Average outside temperature
3 Room temperature
(optional)
4 Temperature of the energy source,
(e.g.boiler, buf-
fer)
5 Flow temperature of the heating circuit
6 Position of the heating circuit mixer
0 % - the mixer is closed, the heating circuit is supplied from
the heating circuit return.100% - the mixer is open, the hea-
ting circuit is supplied from the heating boiler flow.
7 Info line: Heating requirement (Yes/No) to the
energy source.
8 Status line of the heating circuit
9 Heating circuit settings
10 Display of the heating circuit operating mode
set on the optional room temperature controller
(Art. no. 6160)
6.1 Heating circuit settings
Fig. 2-25
1 Heating circuit operating mode
2 Room settings
(Button is only visible when the
Room effect
parameter is
set to
On
or
Sliding
; this can be found in the
Specialist per-
sonnel system parameters)
3 General settings
4 Heating curve
6.1.1 Heating circuit operating mode
Heating mode
The heating circuit pump is activated. A shutdown
occurs whenever
–
the
external shutdown temperature for heating
mode
is reached
–
when a room temperature sensor is used and
where
room nominal temperature for heating mode
has been reached.
The heating circuit is supplied with the
calculated inlet
nominal temperature
.
Reduced mode
Heating circuit pump is activated. A shutdown occurs
whenever
–
the
external shutdown temperature for reduced
mode
is reached.
–
a room temperature sensor is used and where
room target temperature for reduced mode
has
been reached.
The heating circuit is provided with the reduced tem-
perature, i.e.
calculated inlet nominal temperature
minus
reduction
18
Operation manual
pellettop